Information technology — Cross-jurisdictional and societal aspects of implementation of biometric te...
ISO/IEC 24779-4:2017 contains a set of symbols, icons and pictograms to help the general public understand the concepts and procedures for using electronic systems that collect and/or process fingerprints. This set of symbols, icons and pictograms is designed to be used to
- identify the type of biometric device,
- provide static instructions related to a fingerprint device,
-…
Information technology - Cross-jurisdictional and societal aspects of implementation of biometric te...
ISO/IEC 24779-4:2017 contains a set of symbols, icons and pictograms to help the general public understand the concepts and procedures for using electronic systems that collect and/or process fingerprints. This set of symbols, icons and pictograms is designed to be used to
- identify the type of biometric device,
- provide static instructions related to a fingerprint device,
-…
NORME SUR LES EXTINCTEURS AUX AGENTS PROPRES À L’HALOCARBURE
1.1 Ces exigences visent la construction et le fonctionnement des extincteurs portatifs aux agents
propres à l’halocarbure. Elles ne visent toutefois pas le fonctionnement au cours des essais de réaction
au feu. Les extincteurs aux agents propres à l’halocarbure sont destinés à être utilisés conformément à
la Standard for Portable Fire Extinguishers, NFPA 10 et au Code national de prévention…
Représentation et échange des données relatives aux outils coupants — Partie 305: Création et échang...
Le présent document spécifie un concept pour la conception des éléments relatifs aux outils, limité à tous les types de systèmes d'outillage modulaires à cartouches réglables pour l'alésage, utilisant les propriétés et domaines de valeurs associés.
Le présent document spécifie une façon commune de concevoir des modèles simplifiés contenant les éléments suivants:
— des…
1.1
This Standard applies to newly produced vented gas-fired space heating appliances (see Clause 3,
Definitions), hereinafter referred to as appliance(s), constructed entirely of new, unused parts and
materials, and having input ratings up to and including 400,000 Btu/hr (117 228 W).
These appliances are for use with:
a) natural gas;
b) manufactured gas;
c) mixed gas;
d) propane gas […
Infection control during construction, renovation, and maintenance of health care facilities
1.1
This Standard specifies precautionary and remedial measures, including quality system requirements, for preventing exposure to agents released or augmented because of actions undertaken during health care facility construction, renovation, maintenance, and repair work.
1.2
This Standard is intended to apply to the activities of the following individuals or groups in relation to any aspect…
Low-voltage switchgear and controlgear — Part 7-1: Ancillary equipment — Terminal blocks for copper ...
This part of IEC 60947 specifies requirements for terminal blocks with screw-type or screw-less-type
clamping units primarily intended for industrial or similar use and to be fixed to a support to provide
electrical and mechanical connection between copper conductors. It applies to terminal blocks intended to
connect round copper conductors, with or without special preparation, having a cross-…
Low-voltage switchgear and controlgear — Part 7-2: Ancillary equipment — Protective conductor termin...
This part of IEC 60947 specifies requirements for protective conductor terminal blocks with PE function
up to 120 mm2 (250 kcmil) and for protective conductor terminal blocks with PEN function equal to and
above 10 mm2 (AWG 8) with screw-type or screwless-type clamping units, primarily intended for industrial
applications.
NOTE: AWG is the abbreviation of “American Wire Gage” [Gage (US) = Gauge (…
Low-voltage switchgear and controlgear — Part 7-3: Ancillary equipment — Safety requirements for fus...
1.1 Scope
This part of IEC 60947 applies to fuse terminal blocks with screw-type or screwless-type clamping units
for the connection of rigid (solid or stranded) or flexible copper conductors for the reception of cartridge
fuse-links in accordance with IEC 60127-2, intended primarily for industrial or similar use in circuits not
exceeding 1 000 V a.c., up to 1 000 Hz or 1 500 V d.c., and having a…
Safety requirements for electrical equipment for measurement, control and laboratory use — Part 031:...
1.1.1 Probe assemblies included in scope
This part of IEC 61010 specifies safety requirements for hand-held and hand-manipulated probe
assemblies of the types described below, and their related accessories. These probe assemblies are for
direct electrical connection between a part and electrical test and measurement equipment. They may be
fixed to the equipment or be detachable accessories…