Guidance for performance grading of recovered reverse osmosis (RO) membranes for water reuse
This document provides guidance and requirements for grade classification of performance of recovered reverse osmosis (RO) membranes for water reuse systems.
This standard is applicable to the spiral-wound type of recovered membranes from seawater reverse osmosis (SWRO) and brackish water reverse osmosis (BWRO) systems.
This standard is to ensure consistency in the performance of recovered RO…
Building automation and control systems (BACS) — Part 6: Data communication conformance testing
This standard provides a comprehensive set of procedures for verifying the correct implementation of each capability claimed on a BACnet PICS including:
(a) support of each claimed BACnet service, either as an initiator, executor, or both,
(b) support of each claimed BACnet object-type, including both required properties and each claimed optional property,
(c) support of the BACnet network layer…
Corrosion of metals and alloys — Corrosion and fouling in industrial cooling water systems — Part 1:...
This document specifies general requirements and parameters for the pilot test evaluation of corrosion and scaling control additives in open recirculating cooling water systems. This document covers parameters including test unit design, operation, water quality and contamination. It also covers the design and operation of pilot test devices as well as parameters to be evaluated in pilot test…
High-voltage switchgear and controlgear - Part 307: Guidance for the extension of validity of type t...
IEC TR 62271-307:2024 RLV contains both the official IEC International Standard and its Redline version. The Redline version is available in English only and provides you with a quick and easy way to compare all the changes between the official IEC Standard and its previous edition.
IEC TR 62271-307:2024 refers to prefabricated metal-enclosed and solid-insulation enclosed (both hereinafter…
Plastics — Determination of the viscosity of polymers in dilute solution using capillary viscometers...
This document specifies the general conditions for the determination of the reduced viscosity, intrinsic viscosity and K‑value of organic polymers in dilute solution. It specifies the standard parameters that are applied to viscosity measurement.
This document is applicable to develop standards for measuring the viscosities in solution of individual types of polymer. It is also applicable to…
Online Voting – Part 1: Implementation of Online Voting in Canadian Municipal Elections
Scope
This standard specifies (1) technical design requirements for online voting services and (2) best practices for election administrators who are implementing online voting in Canadian municipal elections. These are separated into two sections in the standard.
While there are types of telephone voting that use an internet connection, any type or form of telephone voting would be subject to…
1 Scope
1.1 These requirements cover bare and covered ferrules intended for field wiring and factory wiring for
use in accordance with the National Electrical Code, NFPA 70 and Canadian Electrical Code, Part I, CSA
C22.1.
1.2 This standard applies to ferrules that are intended to facilitate the connection of stranded wire on to
devices, such as terminal blocks. Their purpose is to treat…
Household and similar electrical appliances — Safety — Part 2-118: Particular requirements for profe...
1 Scope
This clause of Part 1 is replaced by the following.
This part of IEC 60335 deals with the safety of appliances for making ice cream and artisan
gelato.
Appliances taken into account are those intended for commercial use and similar appliances
not intended for normal household use but which may nevertheless be a source of danger to
the public, such as appliances intended to be used…
Safe use of energy-based medical and surgical devices in health care
1 Scope
1.1 Safety guidance for use of energy-based medical and surgical devices
This Standard presents guidance to ensure the safety of persons at risk in locations where energy-based medical and surgical devices are used. This includes but is not limited to guidance on purchasing, education, training, installation, use, servicing, maintenance, engineering and administrative controls, and…
Scope
1.1 These requirements cover electrically operated single and multiple station smoke alarms intended for
open area protection in indoor locations and portable smoke alarms used as "travel" alarms in accordance
with:
a) In Canada:
1) Installation of Smoke Alarms, ULC 553;
2) National Building Code of Canada; and
3) National Fire Code of Canada.
b) In the United States: