Aviation turbine fuel (Military grades F-34, F-37 and F-44)
This standard applies to three grades of aviation turbine fuel (military grades F-34, F-37 as its equivalent, and F-44) consisting of conventional hydrocarbons, synthetic hydrocarbons, naturally occurring non-hydrocarbons and additives as specified herein. Grade F-34 is a kerosene-type aviation turbine fuel, and grade F-44 is a high-flash kerosene-type aviation turbine fuel. Kerosene-type…
Éditeur :
ONGC
Statut :
Annulée
Date de publication :
2020-09-30
Code(s) de l'ICS :
75.160.20
Aviation turbine fuel (Grades JET A and JET A-1)
This standard applies to two grades of kerosene-type aviation turbine fuel (grades JET A and JET A-1), consisting of conventional hydrocarbons, synthetic hydrocarbons, naturally occurring non-hydrocarbons and additives as specified herein. The fuels are normally used in civil aviation operations. The two grades differ only in freezing point. Grade JET A has a maximum freezing point of -40°C…
Éditeur :
ONGC
Statut :
Annulée
Date de publication :
2020-09-30
Code(s) de l'ICS :
75.160.20
Enclosures for electrical equipment, environmental considerations
1 Scope 1.1 This standard applies to enclosures for electrical equipment intended to be installed and used in nonhazardous locations in accordance with the Canadian Electrical Code, Part I, CSA C22.1, the provisions of the National Electrical Code, NFPA 70, and the provisions of Mexico's Electrical Installations, NOM-001- SEDE, as follows: a) Enclosures for indoor locations, Types 1, 2…
Éditeur :
CSA
Statut :
Norme
Date de publication :
2020-09-30
Code(s) de l'ICS :
21.180
Low-voltage switchgear and controlgear — Controllers for drivers of stationary fire pumps
1 Scope and object This International Standard applies to controllers intended for starting, controlling and stopping stationary fire pumps, including automatic and non-automatic types for alternating current electric motor or diesel engine-driven fire pumps. It is anticipated that a controller only controls a single driver. Controllers for electric motor-driven fire pumps always include…
Éditeur :
CSA
Statut :
Norme
Date de publication :
2020-09-29
Code(s) de l'ICS :
29.130.10
Isobutene-isoprene rubber (IIR) — Evaluation procedure
This document specifies: — the physical and chemical tests on raw rubbers, and — the standardized materials, a standardized test formulation, equipment, and processing methods for evaluating the vulcanization characteristics of all types of isobutene-isoprene rubber (IIR).
Éditeur :
ISO
Statut :
Publié
Date de publication :
2020-09-29
Code(s) de l'ICS :
83.060
Surface mounted piezoelectric devices for frequency control and selection - Standard outlines and te...
IEC 61837-2:2018+A1:2020 deals with standard outlines and terminal lead connections as they apply to surface-mounted devices (SMD) for frequency control and selection in ceramic enclosures, and is based on IEC 61240:2016. This edition includes the following significant technical changes with respect to the previous edition: a. revision of the figures to match the notation of the drawings of IEC…
Éditeur :
IEC
Statut :
Publié
Date de publication :
2020-09-23
Code(s) de l'ICS :
31.140
Surface mounted piezoelectric devices for frequency control and selection - Standard outlines and te...
IEC 61837-2:2018+A1:2020 deals with standard outlines and terminal lead connections as they apply to surface-mounted devices (SMD) for frequency control and selection in ceramic enclosures, and is based on IEC 61240:2016. This edition includes the following significant technical changes with respect to the previous edition: a. revision of the figures to match the notation of the drawings of IEC…
Éditeur :
IEC
Statut :
Publié
Date de publication :
2020-09-23
Code(s) de l'ICS :
31.140
Cardiovascular implants — Endovascular devices — Part 2: Vascular stents
This document specifies requirements for the evaluation of stent systems (vascular stents and delivery systems) and requirements with respect to nomenclature, design attributes and information supplied by the manufacturer, based upon current medical knowledge. Guidance for the development of in vitro test methods is included in Annex D. This document is supplemental to ISO 14630, which specifies…
Éditeur :
ISO
Statut :
Publié
Date de publication :
2020-09-21
Code(s) de l'ICS :
11.040.40
Communication networks and systems for power utility automation - Part 90-11: Methodologies for mode...
IEC TR 61850-90-11:2020(E), which is a Technical Report, describes the methodologies for the modelling of logics for IEC 61850 based applications in power utility automation. In particular, it describes the functional view of logic based on existing logical nodes for generic process automation and the operational modes of the logic. Furthermore it includes the specification of the standard…
Éditeur :
IEC
Statut :
Publié
Date de publication :
2020-09-21
Code(s) de l'ICS :
33.200
Medical electrical equipment - Part 2-35: Particular requirements for the basic safety and essential...
IEC 60601-2-35:2020 applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of HEATING DEVICES using BLANKETS, PADS or MATTRESSES in medical use, also referred to as ME EQUIPMENT. HEATING DEVICES intended to prewarm a bed are included in the scope of this document. If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only, or to ME SYSTEMS only, the title and content…
Éditeur :
IEC
Statut :
Publié
Date de publication :
2020-09-20
Code(s) de l'ICS :
11.040.01; 11.140