Warehousing, storage, and transportation of clean and sterile medical devices
Scope
1.1
This Standard specifies requirements and recommended practices for the warehousing, storage, handling, and transportation of clean and sterile medical devices in facilities where open-inventory (split-case) storage and handling services are provided.
1.2
This Standard covers
(a) physical and functional requirements for warehouses, storerooms, and other storage facilities that…
Electrostatics - Part 4-6: Standard test methods for specific applications - Wrist straps
IEC 61340-4-6:2010 provides electrical and mechanical test methods and performance limits for evaluation, acceptance and functional testing of wrist straps. This standard is intended for testing wrist straps and wrist strap systems used for the grounding of personnel engaged in working with ESD sensitive assemblies and devices. It does not address constant monitoring systems.
Electrostatics - Part 4-6: Standard test methods for specific applications - Wrist straps
IEC 61340-4-6:2010 provides electrical and mechanical test methods and performance limits for evaluation, acceptance and functional testing of wrist straps. This standard is intended for testing wrist straps and wrist strap systems used for the grounding of personnel engaged in working with ESD sensitive assemblies and devices. It does not address constant monitoring systems.
This International Standard applies to open-cycle gas-turbine power plants using combustion systems supplied with gaseous and/or liquid fuels as well as closed-cycle and semi-closed-cycle gas-turbine power plants. It can also be applied to gas turbines in combined cycle power plants or in connection with other heat-recovery systems.
In cases of gas turbines using free-piston gas generators or…
Live working - Voltage detectors - Part 3: Two-pole low-voltage type
IEC 61243-3:2009 is applicable to hand-held two-pole voltage detectors with its accessories (crocodile clips and detachable leads) to be used in contact with parts of electrical systems:
- for a.c. voltages not exceeding 1 000 V at nominal frequencies between 16 2/3 Hz and up to 500 Hz, and/or
- for d.c. voltages not exceeding 1 500 V.
Voltage detectors covered by this standard are intended to…
Space systems — Space environment (natural and artificial) — Model of the earth's magnetospheri...
ISO 22009:2009 describes the main magnetospheric large-scale current systems and the magnetic field in the earth's magnetosphere and provides the main requirements for a model of the magnetospheric magnetic field. Ionospheric currents are not considered in ISO 22009:2009. ISO 22009:2009 includes a worked example of the model and establishes the parameters of magnetospheric large-scale…
ISO 22966:2009 gives common requirements for the execution of concrete structures and applies to both in-situ works and construction using prefabricated concrete elements.
ISO 22966:2009 requires that the execution specification state all the specific requirements relevant to the particular structure.
ISO 22966:2009 is applicable to temporary as well as permanent concrete structures.
Additional…
ISO 29945:2009 specifies a manual sampling method for refrigerated liquefied DME at terminals in both loading and unloading ports. ISO 29945:2009 also specifies detailed precautions to ensure safety during sampling work. However, safety measures, proposed for equipment being used for sampling, such as sampling lines and sample cylinders, are limited to general terms because they are governed…
This National Standard of Canada is applicable to electrical insulating blankets for the protection of workers from accidental contact with live or earthed electrical conductors, apparatus or circuits and avoidance of short circuits on electrical installations.
Electrical insulating blankets in rolls having a width lower than 50 mm are not covered by this
standard.
This National Standard of Canada covers insulating ropes that are utilized during live working
procedures in contact with parts of installations operating at voltages up to and including
800 kV r.m.s.
Insulating ropes for live working procedure under rain and/or d.c. conditions are not covered…