Construction procurement — Part 3: Standard conditions of tender
This document sets out standard conditions of tender which
bind the employer and tenderer to behave in a particular manner,
establish what a tenderer is required to do in order to submit a compliant tender,
make known the evaluation criteria to tenderers, and
establish the manner in which the employer conducts the process of offer and acceptance and provide the necessary feedback to tenderers on…
Construction procurement — Part 4: Standard conditions for the calling for expressions of interest
This document sets out standard conditions for the calling for expressions of interest which
a) bind the employer and respondent to behave in a particular manner,
b) establish what is required for a respondent to submit a compliant submission,
c) make known to respondents the evaluation criteria, and
d) establish the manner in which the employer conducts the process of calling for expressions of…
Power installations exceeding 1 kV AC and 1,5 kV DC - Part 1: AC
IEC 61936-1:2021 CMV contains both the official standard and its commented version. The commented version provides you with a quick and easy way to compare all the changes between IEC 61936-1:2021 CMV edition 3.0 and the previous IEC 61936-1:2010+AMD1:2014 CSV edition 2.1. Futhermore, comments from IEC TC 99 experts are provided to explain the reasons of the most relevant changes.
IEC 61936-1:…
Power installations exceeding 1 kV AC and 1,5 kV DC - Part 1: AC
IEC 61936-1:2021 provides requirements for the design and the erection of electrical power installations in systems with nominal voltages exceeding 1 kV AC and nominal frequency up to and including 60 Hz, so as to provide safety and proper functioning for the use intended.
This document does not apply to the design and erection of any of the following:
– overhead and underground lines between…
Water quality — Determination of microcystins — Method using liquid chromatography and tandem mass s...
This document specifies a method for the quantification of twelve microcystin variants (microcystin-LR, -LA, -YR, -RR, -LY, -WR, -HtyR, -HilR, -LW, -LF, [Dha7]-microcystin-LR, and [Dha7]-microcystin-RR) in drinking water and freshwater samples between 0,05 µg/l to 1,6 µg/l. The method can be used to determine further microcystins, provided that analytical conditions for chromatography and mass…
Live working - Methods for assessment of defects and verification of performance applicable to tools...
IEC 61318:2021 This document defines methods to assess defects and to verify that products after the manufacturer process meet the requirements of the corresponding product standard.
The principles of assessment of defects for live working products are detailed in this document to assist product standard developers in prescribing the best means to achieve suitable quality of every finished tool…
Wearable electronic devices and technologies - Part 250-1: Electronic textile - Snap fastener connec...
IEC TR 63203-250-1:2021(E) reviews the use cases of conductive snap fasteners applied as electrical connectors for e-textile products available on the market and provides guidance on future standardization works.
Energy management system application program interface (EMS-API) - Part 600-1: Common Grid Model Exc...
IEC 61970-600-1:2021 covers the definition of Common Grid Model Exchange Standard (CGMES), defines the main rules and application’s requirements to meet business requirements for assembled and merged model to fit relevant business services. This document does not define the business requirements, business processes nor how applications are implemented. This document defines how relevant Common…
Energy management system application program interface (EMS-API) - Part 600-1: Common Grid Model Exc...
IEC 61970-600-1:2021 covers the definition of Common Grid Model Exchange Standard (CGMES), defines the main rules and application’s requirements to meet business requirements for assembled and merged model to fit relevant business services. This document does not define the business requirements, business processes nor how applications are implemented. This document defines how relevant Common…
Ideal state benchmarking and application of benchmark energy factor for data centres
1 Scope
1.1
This Standard specifies the framework and calculation models for “essential energy benchmarking” of data centres as a new form of ideal-state benchmarking for energy performance. It provides the specifications necessary to benchmark the energy efficiency performance of a data centre by using a dimensionless indicator called the benchmark energy factor (BEF).
This Standard is a…