1. Scope
1.1 General
This standard provides requirements for the design, manufacture, construction, modification, operation, inspection, testing, and maintenance of passenger ropeways and conveyors.
Requirements for abnormal or unusual conditions are not specifically provided for, nor are all the details of engineering and construction prescribed. It is intended that all work…
Medical Electrical Equipment - Part 2: Particular Requirements for the Safety of Gamma Beam Therapy ...
This National Standard of Canada is equivalent to International Standard CEI/IEC 60601-2-11:1997, (second edition, 1997-08).
1 Scope and Object
This clause of the General Standard applies as follows:
1.1 Scope
Addition:
aa)
This Particular Standard specifies requirements for the safety of GAMMA BEAM THERAPY EQUIPMENT intended for RADIOTHERAPY in human medical practice and includes EQUIPMENT…
Information technology — Open Distributed Processing — Type Repository Function
The concept of "type" is fundamental to ODP systems; the interaction model of ODP-RM involves strongly-typed
interactions.
This Recommendation | International Standard:
? defines a framework for describing types of interest in ODP systems by determining what entities need to
be typed and what needs to be said about the identified types. The primary focus of this work is the…
Information technology - Open Distributed Processing - Type Repository Function
The concept of "type" is fundamental to ODP systems; the interaction model of ODP-RM involves strongly-typed
interactions.
This Recommendation | International Standard:
? defines a framework for describing types of interest in ODP systems by determining what entities need to
be typed and what needs to be said about the identified types. The primary focus of this work is the…
1. Scope
1.1 General
This Standard covers wrought steel flanges primarily intended for use in oil or gas pipeline systems.
1.2 Size, Grade, Nominal Pressure Class, and Category
1.2.1 Size
This Standard covers flanges in sizes from NPS 1/2 to NPS 60, inclusive. (Refer to Appendix A, Table A1.)
1.2.2 Grade
This Standard covers flanges from Grade 248 to Grade 483, inclusive.…
1. Scope
1.1 General
This Standard covers steel valves primarily intended for use in oil or gas
pipeline systems. The following types of valves are covered:
(a) gate valves;
(b) plug valves;
(c) ball valves; and
(d) check valves.
1.2 Size, Nominal Pressure Class, and Category
1.2.1 Size
This Standard covers valves in sizes from NPS 2 to NPS 60, inclusive. (Refer
to…
Documentation on design automation subjects - Part 1: EDA industry standards roadmap
The EDA Standards Roadmap Workshop was sponsored by the CAD Framework Initiative (CFI), Electronic Design Automation Companies (EDAC), and SEMATECH with participation by interested industry groups. The Workshop was specifically aimed at developing an
industry-wide roadmap for development of design and test standards within Electronic Design Automation (EDA).
There were three working groups, each…
Commentary on CSA Standard Z662-99, Oil and Gas Pipeline Systems
1. Scope
1.1
The scope statement indicates which aspects and parts of pipeline systems and which service fluids are
covered by the Standard.
? Carbon dioxide was added as a new service fluid in 1996. The definition of gas was changed in 1983 to accommodate the coverage of gaseous service fluids other than fuel gas and sour gas; however, until 1996, none had been added.
? The carbon…
Alarm systems - Part 7-2: Message formats and protocols for serial data interfaces in alarm transm...
Specifies a common application layer protocol (message structure, formats and transmission procedures) to be used at standard interfaces in alarm transmission systems. Should be used at all such interfaces where equipment from one supplier is intended to inter-work with equipment from other suppliers.
Alarm systems - Part 7-4: Message formats and protocols for serial data interfaces in alarm transm...
Specifies the transport layer message structure, formats and transmission procedures to be used at standard interfaces in alarm transmission systems. Should be used at all such interfaces where equipment from one supplier is intended to inter-work with equipment from other suppliers, and where the underlying system architecture does not provide the necessary facilities to support the common…