Câbles multiconducteurs à paires symétriques et quartes pour transmissions numériques - Partie 3-1: ...
Determines the layout and style for detail specifications describing multicore and symmetrical pair(s)/quad(s) cables for digital communication in work area wirin. Detail specifications based on the blank detail specification may be prepared by a national standards organization, a manufacturer or a user.
Infection Control During Construction or Renovation of Health Care Facilities
Scope
1.1
This Standard describes precautionary and remedial measures for preventing exposure to agents released or augmented because of actions undertaken during health care facility construction, renovation, maintenance, and repair work.
Notes:
1) In this Standard, the term 'construction' includes not only construction but also renovation, maintenance, and repair work, unless the…
Is applicable to fully insulating spliced or hook ladders with extension or having a combination of insulating and conductive sections and used for live working on a.c. or d.c. electrical installations at 1 000 V and above for a.c. and 1 500 V and above for d.c. This standard concerns only ladders made of synthetic material. These ladders are used, to provide access, generally on overhead line…
Selection, Use, Maintenance, and Laundering of Reusable
Textile Wrappers, Surgical Gowns, and Drape...
1 Scope
1.1
This Standard defines essential elements in the selection, use, maintenance, continued serviceability, and laundering of reusable textile wrappers, surgical gowns, and drapes for use in health care facilities. Included in the selection criteria are minimum construction and performance requirements for reusable textiles to help health care facilities choose products with barrier…
1 Scope
This Standard sets forth requirements and guidance pertaining to the various sea operations involved with fixed and floating offshore structures. As sea operations are complex activities specific to each application, these requirements should be reviewed for each application to ensure that the particular circumstances are adequately addressed.
Braking systems of rubber-tired machines - Performance requirements and test procedure
This National Standard of Canada is based on International Standard ISO 3450:1996, (third edition, 1996-04-01).
1 Scope
This International Standard specifies minimum performance and test criteria for brake systems to enable uniform assessment of the braking capability of earth-moving machinery which operates on work sites or travels on public roads. Service secondary, and parking brake systems…
Part 1
1 Scope
1.1
Except as indicated in Clause 1.2, Part 1 of this Standard applies to all boilers, pressure vessels, pressure piping, and fittings, as provided for by the Act (as defined in Clause 3) and identified in Part 1 of this Standard.
Notes:
1) In certain provinces there may be variations in the size limitations specified in Part 1 of this Standard. The regulatory…
Household and similar electrical appliances - Safety - Part 2-99: Particular requirements for commer...
Deals with the safety of electrically operated commercial hoods intended for installation above commercial cooking appliances such as ranges, griddles, griddle grills and deep fat fryers, and not intended for household use. The hoods included in this standard are used, for example in restaurants, canteens, hospitals, and commercial enterprises such as bakeries, butcheries. The rated voltage being…
Industrial Robots and Robot Systems - General Safety Requirements
1 Scope
1.1 Scope
This safety Standard applies to the manufacture, remanufacture, rebuild, installation, safeguarding, maintenance and repair, testing and start-up, and personnel training requirements for industrial robots and robot systems.
1.2 Purpose
The purpose of this Standard is to provide requirements for industrial robot manufacture, remanufacture, and rebuild; robot system integration/…
Specifies the performance requirements for three classes of sound calibrator: laboratory standard (class LS), class 1 and class 2. Tolerance limits are smallest for class LS and greatest for class 2 instruments. Class LS sound calibrators are normally used only in the laboratory; class 1 and class 2 are considered as sound calibrators for field use. A class 1 sound calibrator is primarily…