Large yachts — Strength, weathertightness and watertightness of glazed openings — Part 1: Design cri...
This document specifies technical requirements for independent glazed openings on large yachts, taking into account navigation conditions, the location of the opening and the materials, framing and testing.
Large yachts are yachts with length of the hull, LH, higher or equal to 24 m, used for sport or pleasure and commercial operations.
This document is suitable for the design of glazed openings…
Series capacitors for power systems - Part 1: General
IEC 60143-1:2015+AMD1:2023 CSV applies both to capacitor units and capacitor banks intended to be used connected in series with an a.c. transmission or distribution line or circuit forming part of an a.c. power system having a frequency of 15 Hz to 60 Hz. The primary focus of this standard is on transmission application. The series capacitor units and banks are usually intended for high-voltage…
Medical electrical equipment - Part 2-21: Particular requirements for the basic safety and essential...
IEC 60601-2-21:2020+AMD1:2023 CSV applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of INFANT RADIANT WARMERS as defined in 201.3.204, also referred to as ME EQUIPMENT. If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only, or to ME SYSTEMS only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause…
Standard for Diesel Engines for Driving Stationary Fire Pumps
Scope
1.1 These requirements cover diesel engines for driving centrifugal fire pumps.
1.2 The engines covered by these requirements are intended for installation and use in accordance with
the Standard for the Installation of Stationary Fire Pumps for Fire Protection, NFPA 20.
Les moteurs diesel d’entrainement des pompes d’incendie stationnaires
Domaine d’application
1.1 Ces exigences concernent les moteurs diesel d’entrainement des pompes d’incendie centrifuges.
1.2 Les moteurs concernés par ces exigences sont destinés à être installés et utilisés conformément à la
Standard for the Installation of Stationary Fire Pumps for Fire Protection, NFPA 20.
Aerospace — Nuts, self-locking, with maximum operating temperature less than or equal to 425 °C — Te...
This document specifies test methods for metric self-locking nuts with MJ threads intended for use in aerospace construction at maximum operating temperatures less than or equal to 425 °C. It describes the test device and the method for each test.
It applies to self-locking nuts as defined above, provided that the relevant documents (dimensional standard, drawing, procurement specification, etc…
Scope
Purpose
This standard enables health and social services organization leaders and organizational clinical decision-making teams to develop or improve the clinical governance structure and implement clinical governance practices to improve the delivery of clinical programs and services, care experiences, and care outcomes across the continuum of care.
Applicability
This standard applies…
1 Scope
1.1 Inclusions
This Standard applies to newly produced automatic valves constructed entirely of new, unused parts and materials. These valves can be individual automatic valves or valves utilized as parts of automatic gas ignition systems.
This Standard also applies to commercial/industrial safety shutoff valves herein after referred to as C/I valves.
Components performing functions…
1 Scope
1.1 This standard applies to quick-connect terminals, both connectors and tabs, having nominal widths
of 2.8, 3.2, 4.8, 5.2, and 6.3 mm (0.110, 0.125, 0.187, 0.205, and 0.250 in). They are intended for internal
wiring connections in electrical equipment and for the field termination of conductors to electrical
equipment in accordance with Part I of the Canadian Electrical Code, CSA…
1 Scope
1.1 The requirements in this standard cover sealed wire connector systems, including insulating caps,
covers, resins, tubing, and tapes provided with, or for use with, specific wire connectors. These systems
are intended for wet or damp locations and other installations such as:
a) Direct burial,
b) Below grade,
c) Above grade where exposed to sunlight; or
d) Where exposed to sea…