1 Scope
1.1
This Standard covers the material properties and the manufacturing requirements of fibre-reinforced polymer (FRP) bars or bars that are part of a grid for use in non-prestressed internal reinforcement of concrete components of structures (e.g., bridges, buildings, and marine structures).
1.2
This Standard covers FRPs that comprise
a)
E-CR glass, carbon, aramid, or basalt…
1 Scope
This part of IEC 61400 deals with safety philosophy, quality assurance, and engineering
integrity and specifies requirements for the safety of small wind turbines (SWTs) including
design, installation, maintenance and operation under specified external conditions. Its
purpose is to provide the appropriate level of protection against damage from hazards from
these systems during…
Test methods for evaluating material compatibility in compressed hydrogen applications — Polymers
1 Scope
1.1
This Standard provides uniform test methods for evaluating material compatibility in compressed hydrogen applications. The results of these tests are intended to provide a basis for comparison of materials performance in applications using compressed hydrogen.
1.2
This Standard applies to polymer materials only.
Note: In this Standard, the term “polymer” refers to synthetic…
1.1 This Standard prescribes inspection and test procedures for the purpose of verifying that the fire
alarm system is installed in conformance with the design and CAN/ULC-S524, Standard for Installation of
Fire Alarm Systems, and performs all of its intended functions as designed.
NOTE 1: This Standard is intended to apply to both required and voluntary fire alarm installations.
NOTE 2:…
STANDARD FOR INSPECTION AND TESTING OF FIRE ALARM SYSTEMS
1.1 This Standard prescribes requirements for the inspection and testing of fire alarm systems; and
specifies the devices and functions to be inspected, tested, and documented for the periodic inspection
and test.
NOTE 1: This Standard is intended to apply to both required and voluntary fire alarm installations.
NOTE 2: Refer to Annex A (Informative), Informative Materials, A1.1.
Telecommunications and information exchange between information technology systems - Requirements fo...
This standard defines profiles that select features, options, configurations, defaults, protocols and procedures of bridges, stations, and LANs that are necessary to build networks that are capable of transporting fronthaul streams, which are time-sensitive.
NOTE—Stream and flow are used as synonyms in this document.1
NORME DE SÉCURITÉ Relative aux tuyaux et raccords de gicleurs thermoplastiques pour le service de pr...
1.1 Ces exigences s’appliquent aux tuyaux et raccords thermoplastiques utilisés dans des systèmes
d’extincteurs automatiques sous eau pour le service de protection contre les incendies.
1.2 Les tuyaux et raccords thermoplastiques visés par ces exigences sont destinés à une utilisation dans
des systèmes de gicleurs pour les types d’usages suivants :
a) usages à faible risque tels que définis…
Standard for Fixed Condensed Aerosol Extinguishing System Units
1 Scope
1.1 These requirements cover the construction and operation of fixed condensed aerosol extinguishing
system units inclusive of aerosol generating extinguishing system units and aerosol generating automatic
extinguisher units intended for total flooding applications when installed, inspected, tested, and maintained
in accordance with the Standard for Fixed Aerosol Fire Extinguishing…
Protective Clothing for Use in Welding and Allied Processes- Certification Protocol
Scope
This certification program covers protective clothing in the form of a single or two-piece garment, namely a jacket and pants, as well as additional protective clothing garments such as neck curtains hoods, sleeves, aprons and gaiters.
For adequate complete protection of welders against hazards, personal protective equipment (PPE) covered by other standards should be worn in addition…
Telecommunications and information exchange between information technology systems — Requirements fo...
This standard defines profiles that select features, options, configurations, defaults, protocols and procedures of bridges, stations, and LANs that are necessary to build networks that are capable of transporting fronthaul streams, which are time-sensitive.
NOTE—Stream and flow are used as synonyms in this document.1