Breakaway devices for liquefied natural gas (LNG) dispensing systems for natural gas vehicles (NGV)
1 Scope
1.1 General
1.1.1
This Standard applies to newly manufactured LNG dispenser fuelling and vent hose emergency breakaway shutoff devices, hereinafter referred to as devices.
Notes:
1)
Devices covered in this Standard are intended to be used on an LNG dispenser certified to CSA LNG 4.1 and with an LNG refuelling connector in accordance with ANSI/CAN/CSA-ISO 12617.
2)
Both “one-time…
1 Scope
1.1
This Standard specifies general requirements, test methods, and markings for whirlpool and air-jetted bathtubs and suction fittings used in hydromassage bathtub systems that incorporate a bathtub and circulation pump. The circulation pump can be with or without
a)
a piping system; and
b)
induction of air (which can be achieved by integral suction or through an air pump).
1.2…
Installation code for lightning protection systems
1 Scope
1.1
This Standard covers the protection from lightning of
a)
recreational, residential, institutional, medical, agricultural, industrial, commercial, military, and telecommunications buildings and structures;
b)
tall, slender structures such as smokestacks, silos, tanks, towers, masts, and poles;
c)
immobile property such as equipment, tents, fences, trees, and solar arrays; and…
General requirements — Canadian Electrical Code, Part II
1 Scope and object
1.1 Scope of this Standard
This Standard specifies requirements pertaining to the following:
a)
definitions;
b)
construction;
c)
equipment complying with Standards;
d)
safety and protection;
e)
materials and quality of work;
f)
marking; and
g)
tests (of a general nature).
Such requirements are applicable to all individual Standards of the Canadian Electrical…
1 Scope
1.1
This Standard applies to explosion-proof electrical equipment suitable for use in hazardous locations in accordance with CSA C22.1, Canadian Electrical Code, Part I and the requirements of CSA M421. It applies to explosion-proof enclosures, parts of enclosures and other related equipment constructed of metallic and non-metallic materials.
1.2
Other Standards for hazardous location…
Standard test method for the dynamic wind uplift resistance of membrane-roofing systems
1 Scope
1.1
This test method determines the wind uplift resistance of membrane-roofing systems when subjected to dynamic wind load cycles. The test methods are applicable to
a)
mechanically attached membrane roofing systems; and
b)
adhered membrane roofing systems.
The roofing system consists of a deck and roofing membrane. It includes components such as vapour barriers or retarders,…
Hoses for liquefied natural gas (LNG) dispensing systems for natural gas vehicles (NGV)
1 Scope
1.1
This Standard applies to liquefied natural gas metallic hose assemblies that are used on LNG dispensers to connect the dispenser to the refuelling nozzle and for gas lines that carry vented gas back to a safe location within the following service temperature range from –196 °C to +65 °C (–320 °F to +149 °F) and nominal hose size range DN (NPS) from 10 to 50 (3/8 to 2).
1.2
Hose…
Scope
Purpose
CAN/HSO 34015:2020 (E) Primary Health Care Services standard is to be used in conjunction with the following HSO standards, as applicable:
• HSO 1001:2018 – Governance
• HSO 34012:2018 – Leadership for Small, Community-Based Organizations
• HSO 0001:2018 – Service Excellence
• HSO 34011:2018 – Infection Prevention and Control Standards for Community-Based Organizations
• HSO…
Data governance – Part 1: Data protection of digital assets
This Standard specifies minimum requirements for products and/or services providing data protection of digital assets at-rest, in-motion, and in-use across platforms (e.g., endpoints, mobile, cloud), facilitating secure sharing and collaboration across different IT systems within and between organizations.
1 Scope
1.1
This Standard applies to portable luminaires, intended for use in dry, damp, and wet locations, and intended to be used in accordance with the Rules of CSA C22.1, Canadian Electrical Code, Part I, in non- hazardous locations, on a nominal 120 V system and 15 or 20 A branch circuits, or on the load side of a Class 2, LED Class 2, or safety extra-low voltage (SELV) circuit.
1.2
This…