Installation code for propane fuel systems and containers on motor vehicles
1 Scope
1.1
This Code applies to
a)
the installation, servicing, and repair of propane fuel system components and containers on motor vehicles for the provision of motive power; and
b)
the installation of containers on motor vehicles such as recreational vehicles, outdoor food service units, and wash-mobiles when propane is to be used for fuel purposes (other than motive power).
Note: “…
1 Scope
1.1
This Standard applies to decorative lighting strings, decorative lighting outfits, pre-lit trees, and accessories, intended for seasonal or commercial use connected to circuits of 120 V nominal or less by means of an attachment plug, and designed to be used in accordance with the rules of the Canadian Electrical Code, Part I, in non-hazardous locations.
1.2
These requirements…
1 Scope
1.1
This Standard applies to
a)
electrostatic air cleaners intended to remove dust and dirt from the air and intended for general indoor residential and commercial use;
b)
air ionizer type air cleaners;
c)
other similar ionizing equipment; and
d)
duct-mounted type electrostatic air cleaners, air ionizers, and other similar ionizing equipment intended for general indoor…
Secondary cells and batteries containing alkaline or other non-acid electrolytes — Safety requiremen...
1 Scope
This part of IEC 62133 specifies requirements and tests for the safe operation of portable sealed
secondary nickel cells and batteries containing alkaline electrolyte, under intended use and reasonably
foreseeable misuse.
1DV.1 D1 Modification to add the following paragraph and note to Clause 1:
This standard is not, by itself, generally suitable for the evaluation of the safety of…
Interconnection of distributed energy resources and electricity supply systems
1 Scope
1.1
This Standard specifies the technical requirements for the interconnection of distributed energy
resources (DER) and distribution systems up to 50 kV line to line at the point of common coupling (PCC).
1.2
This Standard does not define the maximum DER capacity or the upper voltage limit for installations
that are interconnected with a single PCC or connected to a given feeder.…
1 Scope
1.1 Purpose
The purpose of this Standard is to establish criteria for the design, manufacture, testing, inspection, installation, maintenance, use, and operation of vehicle-mounted aerial devices installed on a chassis, primarily used to position personnel, and for the training of operators for that equipment, to achieve the following objectives:
a)
prevention of personal injuries and…
Preparation and quality management of fluids fo haemodialysis and related therapies — Part 1: Genera...
1 Scope
1.1 General
This document is the base standard for a number of other standards dealing with water treatment
equipment, water, dialysis water, concentrates, and dialysis fluid (ISO 23500 series) and provides
dialysis practitioners with guidance on the preparation of dialysis fluid for haemodialysis and
related therapies and substitution fluid for use in online therapies, such as…
Preparation and quality management of fluids for haemodialysis and related therapies — Part 5: Quali...
1 Scope
This document specifies minimum quality requirements for dialysis fluids used in haemodialysis and
related therapies.
This document includes dialysis fluids used for haemodialysis and haemodiafiltration, including
substitution fluid for haemodiafiltration and haemofiltration.
This document excludes the water and concentrates used to prepare dialysis fluid or the equipment
used in…
Petroleum and natural gas industries — Floating offshore structures — Part 1: Ship-shaped, semi-subm...
1 Scope
This document provides requirements and guidance for the structural design and/or assessment of
floating offshore platforms used by the petroleum and natural gas industries to support the following
functions:
— production;
— storage and/or offloading;
— drilling and production;
— production, storage and offloading;
— drilling, production, storage and offloading.
NOTE 1 Floating…
Secondary cells and batteries containing alkaline or other non-acid electrolytes — Safety requiremen...
1 Scope
This part of IEC 62133 specifies requirements and tests for the safe operation of portable sealed
secondary lithium cells and batteries containing non-acid electrolyte, under intended use and reasonably
foreseeable misuse.
1DV.1 D1 Modification to add the following paragraph and note to Clause 1: