Specification for high-voltage fuse-links for motor circuit applications
Applies primarily to fuse-links used with motors started direct-on-line on alternating current systems of 50 Hz and 60 Hz. Standardizes time-current characteristics to formulate additional pulse withstand requirements regarding testing and to give guidance for the selection of fuse-links to be used with motors.
Note: -Fuse-links according to this specification should comply with the requirements…
Piezoelectric ceramic resonators and resonator units for frequency control and selection - Chapter I...
Establishes uniform conditions for assessing the mechanical and climatic properties of ceramic resonators, describes test methods, gives recommendations for standard values and gives guidance for the use of such resonators.
Non-ionizing radiation hazards in the frequency range from 10 MHz to 300 000 MHz
Summarizes the present position on difference in limits and attitudes towards non-ionizing hazards adopted by a number of different countries, and by the IEC and other international organizations, in standards and recommendations. Has the status of a technical report.
Methods of measurement for radio transmitters. Part 7: Cabinet radiation at frequencies above 1 GHz
Specifies the method which is essentially the same as that described in CISPR publication 11, sub-clause 5.2.2. With this method, emphasis has been laid on simplicity and reproducibility, rather than on rigorous scientific method. lt has been purposely developed for use in an ordinary laboratory room to avoid the use of an expensive anechoic room. The method is intended for type tests but it may…
Establishes safety standards for transportation of passengers on
devices that are usually referred to by the following names:
aerial ropeways, chair lifts, gondola lifts, T-bar lifts, J-bar
lifts, platter lifts (and similar devices), and rope tows. This
Standard does not cover equipment such as cog railways and cable
cars running on rails. This Standard may be applied with
modifications…
Condensed phosphates for industrial use (including foodstuffs) — Determination of chloride content —...
Applicable to products having contents expressed in chlorine equal to or more than 30 mg/kg. Potentiometric titration of the chloride ions with standard volumetric silver nitrate solution in a nitric acid-acetone-water medium, at a temperature below 20 0C, using a silver measurement electrode and a colomel reference electrode or a pair of silver-mercury(I) sulphate electrodes. Has also been…
The Standard specifies certain characteristics of the oil. Descriptions and permissible values are given of aspect, colour, odour, relative density at 20/20 °C, refractive index at 20 °C, optical rotation at 20 °C, miscibility with 70 % (V/V) ethanol at 20 °C, acid value, ester value, ester value after acetylation, carbonyl value, and apparent citronellol (rhodinol) content. Most of the values…
Determination of water — Karl Fischer method (General method)
Two methods of titration depending on whether the end point is detected visually or electrometrically are specified. The visual method is only applicable to colourless solutions but can be used when no electrometric apparatus is available. The electrometric method, whether by direct titration or back-titration, is the more accurate one and for this reason recommended. The principle of the test…
Documentation — Numbering of divisions and subdivisions in written documents
Applies to all kinds of written documents, for example manuscripts, printed works, books, journal articles, directions for use and standards. Numbering of divisions and subdivisions is advocated if this - clarifies the sequence, importance and interrelation of individual divisions and subdivisions; - simplifies search and retrieval of certain passages in the text; - makes possible the citation of…