Raw, refined and boiled linseed oil for paints and varnishes — Specifications and methods of test
Specifies the requirements and gives definitions for the raw materials. 23 C is the standard temperature for the test unless otherwise agreed. Stricter requirements may be agreed between the interested parties. Cancels and replaces the ISO Recommendation R 150-1960.
Electrodynamic test equipment for generating vibration — Methods of describing equipment characteris...
Establishes a list and the standard method of obtaining certain properties. Provides three levels of description to be used. Gives for each of these levels a list of the properties to be specified by the manufacturer in his tender and in his literature.
Complete, filled transport packages — General rules for the compilation of performance test schedule...
Basic terms are described, such as distribution systems, hazards during transport, laboratory test of packagesd, performance test schedules. Specification is given for the standardization of test methods and order of tests, selection and modification of test intensities, selection of package attitude, compilation of test schedules and determination of criteria of acceptance. An annex specifies…
Code of Practice for Safety in Demolition of Structures
1. Scope
1.1 General
1.1.1 This Standard outlines the safety precautions to be observed and procedures to be used before, during, and after demolition operations to provide for the safety of the public, workers, and property.
1.1.2 Demolition procedures for both systematic and rapid progressive failure methods are described. Particular emphasis is given to areas of known concern…
Central Forced Air Unitary Heat Pumps With or Without Electrical Resistance
Heat
1. Scope
1.1 This Standard applies to stationary, central, forced air unitary heat
pumps* rated at 600 V or less, single or polyphase, with or without electric
resistance heating, designed to be used in accordance with the Rules of the
Canadian Electrical Code, Part I. For purposes of this Standard a heat pump is
considered to be an electrically driven device.
* Fore convenience, the…
1. Scope
1.1 This Standard applies to add-on heat pumps for comfort heating or heating
and cooling not exceeding 20 kW in the cooling mode and rated at 600 V or less,
single or polyphase, intended to utilize the fan assemblies and duct work of
the existing installed furnaces to form the complete functional systems where
the existing parts are not covered by this Standard.
Note: For…
Portable Containers for Gasoline and other Petroleum Fuels
1. Scope
1.1 This Standard applies to portable containers of up to and including 5
gallons (25 L) nominal capacity, made from metal or plastic and intended for
the storage and transportation of petroleum fuels, but excludes containers
which are integral with or attached to any object, single-trip containers in
which fuel is prepackaged, and those within the scope of CSA Standard Z102.15…
Specifies the regulations for standard designations by means of ropes. Includes designation of ropes, and of characteristics, the symbols used, as well as examples for the designation of steel wire ropes in text and figure.