Radio-frequency connectors. Part 18: R.F. coaxial connectors with inner diameter of outer conductor ...
Provides basic mating and performance information for a subminiature coaxial connector with butting polytetrafluoroethylene (PTFE) dielectric interface for use with flexible and semi-rigid r.f. cables. The connectors are usable up to a frequency of 35 GHz.
Only the interface dimensions are standardized. Other technical data are supplied for guidance only.
Radio-frequency connectors. Part 19: R.F. coaxial connectors with inner diameter of outer conductor ...
Provides basic mating and performance information for subminiature coaxial connectors with overlapping polytetrafluoroethylene (PTFE) dielectric interface for use with flexible and semi-rigid r.f. cables. The connectors are usable up to a frequency of 3 GHz. Only the interface dimensions are standardized. Other technical data are supplied for guidance only.
The contents of the corrigendum of…
Radio-frequency connectors. Part 20: R.F. coaxial connectors with inner diameter of outer conductor ...
Provides basic mating and performance information for a subminiature coaxial connector for use with flexible and semi-rigid r.f. cables. The connectors are usable up to a frequency of 6 GHz. Only the interface dimensions are standardized. Other technical data are supplied for guidance only.
Radio-frequency connectors. Part 21: Two types of radio-frequency connectors with inner diameter of ...
Standardizes the interface and ratings of two versions of a medium size r.f. connector for use with flexible and semirigid cables. The connectors are recommended to be utilized in medium power and low reflection applications up to 11 GHz. The dielectric filled interface is especially beneficial in applications involving severe environmental exposure. Both versions of this connector type are screw…
1. Scope
1.1 This Standard applies to cord-connected electric clocks intended for use in household and other nonhazardous indoor dry locations in accordance with the Rules of the Canadian Electrical Code, Part I, and having a rating not exceeding 125 V ac and 30 W input and secondary circuits not exceeding 240 V.
1.2 This Standard includes both motor and electronically driven, di…
Applies to the design, based on limit states, of structural
members cold formed to shape from carbon or low alloy steel
sheet, strip or plate up to 25 mm in thickness and intended for
load carrying purposes in buildings. For application of this
Standard to the design of cold formed steel structural members in
structures other than buildings, supplementary specifications
shall be provided…
Specifies minimum performance requirements and test procedures to
asses compliance to those requirements, for hemodialysers,
hemofilters and hemoconcentrators used for kidney dialysis and
associated procedures. The Standard includes requirements for
hemodialysers of coil, hollow fibre and parallel, plate design.
It does not apply to the extracorporeal circuit, plasma filters,
hemoperfusion…
Extracorporeal Circuits for Use with a Hemodialyser, Hemofilter, or
Hemoconcentrator
Specifies minimum performance requirements and test procedures to
assess compliance to those requirements, for the extracorporeal
circuit for use with hemodialysers, hemofilter or
hemoconcentrators used for kidney dialysis and associated
procedures. This Standard applies to blood tubings and accessory
tubings for the extracorporeal circuit. Accessory tubings include
fluid infusion tubing…