Complete filter units for radio interference suppression. Part 2: Sectional specification. Selection...
Applicable to complete filter units for radio interference suppression which fall within the scope of the generic specification. The object of this standard is to prescribe standard requirements for electrical shock hazard protection and standard ratings and characteristics and to select from the generic specification the appropriate methods of test and to give general performance requirements…
Fixed inductors for radio interference suppression. Part 1: Generic specification
Applicable to inductors for radio interference suppression intended for apparatus and machines to be connected to a supply with a nominal voltage not exceeding 500 V between conductors or 250 V between any one conductor and earth and a frequency not exceeding 100 Hz. The combination of two or more inductors within one enclosure is also included in the scope of this standard.
Fixed inductors for radio interference suppression. Part 2: Sectional specification. Selection of me...
Applicable to fixed inductors for radio inteference suppression which fall within the scope of the generic specification. The object of this standard is to prescribe standard requirements for electrical shock hazard protection and standard ratings and characteristics, and to select from the generic specification the appropriate methods of test and to give general performance requirements for…
Complete filter units for radio interference suppression. Part 1: Generic specification
Applicable to complete filter units for radio interference suppression intended for apparatus and machines to be connected to a supply with a nominal voltage not exceeding 500 V between conductors, or 250 V between any one conductor and earth, and a frequency not exceeding 100 Hz. The combination of two or more filters within one enclosure is also included in the scope of this standard.
ISO system of limits and fits — Part 2: Tables of standard tolerance grades and limit deviations for...
This part gives of the limit deviations for commonly used tolerance classes calculated from the information given in ISO 286-1. It covers values for the upper and the lower deviations which are illustrated by a figure. It tabulates numerical values for basic sizes from 3 mm up to and including 3150 mm. An annex gives a graphical review of tolerance zones.
Applies to newly produced outdoor gas grills (see "Definitions",
Part 3) constructed entirely of new, unused parts and materials.
Outdoor gas grills submitted for examination under this Standard
shall be classified as portable or stationary.
1. SCOPe
1.1 This standard applies to a high-density felt with not less than 50% animal
fibre content, for packing, padding and crating, where a firm, semi-hard
material is required. This felt is not intended for use in ammuniation
components.
1.2 For more detailed information on intended uses, see par. 7.2.
1.3 This standard may require the use of materials and/or equipment that…
Testing of Breathing Gas Interruption Monitors for Use During Anaesthesia
1. Scope
1.1
This Standard addresses monitors intended for the detection of interruptions of
the patient's breathing gas during controlled ventilation in anaesthesia by
monitoring pressure in the breathing circuit. It does not address monitors
based on gas composition, flow, or exhaled volume.
Notes:
(1) Applications for critical care ventilation are not considered but may be…
Applies to the design of highway bridges that have spans up to
l00 m, and is based upon the limit states design theory. It sets
forth minimum requirements that are consistent with current
practice. Modifications may be necessary in order to adapt the
Standard for use in the design of a specific bridge, unusual
types of bridges, and bridges with spans longer than 100 m.
Corrosion Preventive Compound, Cold Application, Water Displacing, Soft Film
1.1
This standard applies to a soft film type of solvent-dispersed rust preventive
compound with water displacing properties.
1.2
For details on uses see par. 7.1.