Electric fence energizers - Safety requirements for battery-operated electric
fence energizers suit...
1. Scope
This clause of IEC Publication 1011 is applicable except as follows:
1.1 Replacement:
This standard applies to battery-operated electric fence energizers
suitable for connection to the supply mains.
Mains-operated electric fence energizers incorporating batteries to
supply the energizer if the mains supply is interrupted and…
Electric fence energizers - Safety requirements for battery-operated electric
fence energizers not ...
1. Scope
This clause of IEC Publication 1011 is applicable except as follows:
1.1 Replacement:
This standard applies to battery-operated electric fence energizers not
designed for connection to the supply mains and having rated supply
voltage not exceeding 36 V d.c.
Examples of electric fence energizers within the scope of this standard…
Safety of transportable motor-operated electric tools, Part 1: General
requirements
This National Standard of Canada is based on International Standard CEI/IEC 1029-1:1990.
1 Scope
1.1 This standard applies to electric motor-operated or magnetically-driven
tools, intended for indoor and for outdoor use, which have all the following
characteristics:
a) easily moved by one person, simple devices to facilitate
transportation may be incorporated, e.g. handles,…
Safety of transportable motor-operated electric tools - Part 2: Particular requirements for radial a...
This National Standard of Canada is based on International Standard CEI/IEC 1029-2-2:1993.
1 Scope
This clause of part 1 is applicable except as follows:
1.1 Modification:
Replace the first paragraph by:
This International Standard applies to transportable radial arm saws intended
for cutting wood or similar materials with a blade diameter not exceeding 260
mm as defined in 2.101.
Safety of transportable motor-operated electric tools - Part 2: Particular requirements for planers ...
This National Standard of Canada is based on International Standard CEI/IEC 1029-2-3:1993.
1 Scope
This clause of part 1 is applicable except as follows:
1.1 Modification:
Replace the first paragraph by:
This International Standard applies to planers and thicknessers with a maximum
planing transportable width of 260 mm.
Safety of transportable motor-operated electric tools - Part 2: Particular reqirements for bench gri...
This National Standard of Canada is based on International Standard CEI/IEC 1029-2-4:1993.
1 Scope
This clause of part 1 is applicable except as follows:
1.1 Modification:
Replace the first paragraph by:
This International Standard applies to transportable bench grinders with a
wheel diameter not exceeding 200 mm and a peripheral speed not exceeding 50
m/s, as defined in 2.101.
Safety of transportable motor-operated electric tools - Part 2: Particular requirements for band saw...
This National Standard of Canada is based on International Standard CEI/IEC 1029-2-5:1993.
1 Scope
This clause of part 1 is applicable except as follows:
1.1 Modification:
Replace the first paragraph by:
This International Standard applies to transportable band saws having a length
of the saw band not more than 2 500 mm and band wheels having a diameter of not
more than 315 mm.
Safety of transportable motor-operated electric tools - Part 2: Particular requirements for diamond ...
This National Standard of Canada is based on International Standard CEI/IEC 1029-2-6:1993.
1 Scope
This clause of part 1 is applicable except as follows:
1.1 Modification:
Replace the first paragraph by:
This International Standard applies to transportable diamond drills with water
supply having a core bit diameter of not more than 250 mm.
NOTE - For tools having core bits with a…
Safety of transportable motor-operated electric tools - Part 2: Particular requirements for diamond ...
This National Standard of Canada is based on International Standard CEI/IEC 1029-2-7:1993.
1 Scope
This clause of part 1 is applicable except as follows:
1.1 Modification:
Replace the first paragraph by:
This International Standard applies to transportable diamond saws with water
supply and with a saw blade diameter of not more than 250 mm.
NOTES
1. For tools having saw…
1.1
This Standard applies to 60-250°C multiple conductor jacketed cables and single
or multiple coaxial cables for telephone and other communication circuits such
as voice and data for on-premise customer systems. These cables may contain
one or more optical fiber members. For the purpose of this Standard, a coaxial
cable or coaxial member conductor is considered to be a single conductor with a…