Household and similar electrical air cleaning appliances — Methods for measuring the performance — P...
This document specifies a method to evaluate the capability of portable household air cleaners to reduce the concentration and viability of key experimentally generated bioaerosols in a specified chamber.
Indoor air free of harmful microbes is important to the health of occupants. This is particularly relevant with regard to increased time spent indoors.
Air cleaners are used to reduce the…
Power cables with extruded insulation and their accessories for rated voltages above 30 kV (Um= 36 k...
IEC 60840:2020+AMD1:2023 CSV specifies test methods and requirements for power cable systems, cables alone and accessories alone, for fixed installations and for rated voltages above 30 kV (Um = 36 kV) up to and including 150 kV (Um = 170 kV). The requirements apply to single-core cables and to individually screened three-core cables and to their accessories for usual conditions of installation…
1 Scope
1.1 Inclusions
This Standard applies to structures and hoists that are not a permanent part of buildings, structures, or other works, and that are used during construction, alteration, or demolition to raise and lower persons and/or materials connected with or related to a building project.
This Standard covers the design, construction, installation, maintenance, operation, and…
Test method for rating micro combined heat and power (mCHP) devices
1 Scope
1.1 Applications
This Standard applies to devices meeting the following conditions:
a)
stationary packaged systems designed for single family residential and small commercial applications;
b)
mCHP fuel gas devices, including different prime mover/generator types (e.g., steam, organic Rankine cycle, fuel cell, and IC);
c)
mCHP with net AC electrical output less than 10 kW; and
d…
Energy efficiency and test methodology for EVSE DCFCs
1 Scope
1.1 General
This Standard specifies a test method for calculating the energy efficiency of electric vehicle supply equipment (EVSE) for direct current fast charging (DCFC) across a full range of load conditions. It defines operating modes, and provides energy efficiency minimum requirements for these operating modes.
Note: Many owners and operators of DCFC are concerned with the amount…
Luminaires — Part 2-3: Particular requirements — Luminaires for road and street lighting Luminai...
Scope
This part of the CSA E60598 series of Standards specifies requirements for luminaires for road and
street lighting, tunnel lighting, and column-integrated luminaires with a minimum total height of 2.5 m
above ground level designed to be installed on branch circuits not exceeding 600 V nominal or less
between conductors in accordance with CSA C22.1, Canadian Electrical Code, Part I. It…
Purpose
This standard provides guidance to organizational leaders and members of dedicated mental health teams and addictions teams working in health and social service organizations that provide direct care to people seeking mental health and addictions services.
This standard specifies the accountabilities of organizational leaders and members of dedicated mental health teams and addictions…
Purpose This standard provides guidance to health and social service policy makers, system partners, organization partners, and teams to develop comprehensive, coordinated suicide prevention programs in health and social service settings. The standard does not prescribe the use of a particular approach or treatment, but rather focuses on how a comprehensive, continuous, and coordinated suicide…
Data Governance: Part 5 - Health data and information capability framework
This standard specifies the minimum requirements for organizations to define the depth, diversity and complexity of capabilities, including criteria to assess the degree to which the capability is mature and consistently applied across an organization’s data assets and processes; and
The framework also aims to help networks of organizations (e.g., multiple agencies within a jurisdiction)…
1 Scope
1.1 General
This Standard contains requirements for the material, design, manufacture, marking, and testing of serially produced, refillable Type HGV 2 containers intended only for the storage of compressed hydrogen gas for on-road vehicle operation. These containers
a)
are to be permanently attached to the vehicle;
b)
have a capacity of up to 1000 L (35.4 ft3) water capacity; and…