1.1
This Standard provides requirements and guidance regarding beyond design basis accidents (BDBAs) at existing and new water-cooled reactor facilities with the fundamental objective of protecting the public and environment from the harmful effects of ionizing radiation. This includes
a)
determination of the functional DEC requirements for the structures, systems, and components (SSCs) that…
1.1 General
This Standard specifies requirements for the physical inspection of dwellings, including
a) the systems and components in and around a home that are to be inspected as part of a home
inspection;
b) the minimum extent to which a home is required to be inspected;
c) general methods to be used for
i) the examination and assessment of building components and systems at the time of the…
1.1
This Standard specifies requirements related to the performance, design, testing, labelling, and
provision of instructions for manufactured single-span horizontal lifeline systems (HLL systems) (see
Figure 1). These HLL systems are a component of a complete system for fall arrest.
1.2
This Standard does not apply to
a) HLL systems
i) with span lengths greater than 18.3 m (60 ft);
ii)…
1.1 This Standard covers commercial, freestanding, under-counter, and counter-insert dishwashers,
utensil-washers, and glass washers using water as the principal cleaning medium, hereafter referred to
as dishwashers. These dishwashers utilize steam, gas, or electric heaters for heating the water. Heated
water is provided to a dishwasher by means of steam, gas, or electric heating systems…
Small bore connectors for liquids and gases in healthcare applications - Part 6: Connectors for neur...
ISO 80369-6:2016 specifies requirements for small-bore connectors intended to be used for connections in neuraxial applications. Neuraxial applications involve the use of medical devices intended to administer medications to neuraxial sites, wound infiltration anaesthesia delivery, and other regional anaesthesia procedures or to monitor or remove cerebro-spinal fluid for therapeutic or diagnostic…
Petroleum and natural gas industries — Site-specific assessment of mobile offshore units — Part 1: ...
ISO 19905-1:2016 specifies requirements and guidance for the site-specific assessment of independent leg jack‑up units for use in the petroleum and natural gas industries. It addresses:
manned non-evacuated, manned evacuated and unmanned jack‑ups;
the installed phase at a specific site.
To ensure acceptable reliability, the provisions of this part of ISO 19905 form an integrated…
Paints and varnishes — Evaluation of degradation of coatings — Designation of quantity and size of d...
ISO 4628-7:2016 specifies a method suitable, in particular, for rating the degree of chalking on white or coloured exterior coatings and coating systems on rough surfaces (i.e. those having a roughness greater than segment 4 of the reference comparator G as described in ISO 8503‑1).
The test method specified can also be used for the assessment of the degree of chalking of coatings and coating…
Vitreous and porcelain enamels — Design of bolted steel tanks for the storage or treatment of water ...
ISO 28765:2016 establishes the requirements for the design and use of vitreous-enamel-coated bolted cylindrical steel tanks for the storage or treatment of water or municipal or industrial effluents and sludges.
It applies to the design of the tank and any associated roof and gives guidance on the requirements for the design of the foundation.
It applies where
a) the tank is cylindrical and is…
Procedure for certification of prefabricated buildings, modules, and panels
1.1
This Standard specifies the procedure for certification of prefabricated buildings, and partially or fully enclosed modules and panels for buildings of any occupancy.
It provides requirements for
a)
certification of the factory quality program;
b)
certification of the prefabricated product;
c)
auditing of the factory quality program; and
d)
in-factory inspection of the prefabricated…
Design and installation of ground source heat pump systems for commercial and residential buildings
1.1
This Standard applies to
a)
direct expansion ground source heat pumps for systems using ground heat exchangers as a thermal source or sink for heating and/or cooling, with or without a supplementary heating source; and
b)