Electromagnetic Emissions from Data Processing Equipment and Electronic
Office Machines
1. Scope
1.1 General This Standard establishes limits and methods of measurement of conducted and radiated electromagnetic emissions from data processing equipment and electronic office machines.
1.2 Application This Standard is applicable to data processing equipment and electronic office machines operating at their rated voltage and frequency and in all normal modes of operation.…
Aerials for the reception of sound and television broadcasting in the frequency range 30 MHz to 1 GH...
Applies to linearly polarized receiving aerials for domestic use in the frequency range 30 MHz to 1 GHz. Ensures uniformity in the presentation of aerial performance specifications and provides a standard format for individual aerial specification sheets. This publication supersedes IEC 60138 (1962).
Antennes pour la réception de la radiodiffusion sonore et visuelle dans la gamme de fréquences compr...
S'applique aux antennes de réception à polarisation rectiligne, pour usage domestique, dans la gamme des fréquences comprises entre 30 MHz et 1 GHz. Rend uniforme la présentation des spécifications des antennes et fournit un modèle normalisé pour les cahiers de spécifications. Cette publication remplace la CEI 60138 (1962).
Hearing aids. Part 8: Methods of measurement of performance characteristics of hearing aids under si...
Applies to the performance characteristics of hearing aids. The methods specified in this report require a device such as a manikin to simulate the presence of the wearer. Describes test methods which simulate the acoustical effects of a median adult wearer on the performance of a hearing aid.
This publication has the status of a technical report.
Appareils de correction auditive. Huitième partie: Méthodes de mesure des caractéristiques fonctionn...
S'applique aux caractéristiques fonctionnelles des appareils de correction auditive. Les méthodes spécifiées dans ce rapport nécessitent l'utilisation d'un dispositif du genre mannequin pour simuler la présence du porteur. Décrit des méthodes d'essai qui simulent les effets acoustiques d'un adulte moyen, porteur d'un appareil de correction auditive, sur les…
Electrical installations of buildings. Part 5: Selection and erection of electrical equipment. Chapt...
Considers methods of selection according to installation of current-carrying capacities for non-approved cables having a nominal voltage not exeeding 0.6/1 kV. Provides a series of tables containing the relationship between cross-sectional area of conductors and the load depending on type of conductor material, type of insulation and method of installation.
This publication supersedes IEC 60448.
Isolating transformers and safety isolating transformers. Requirements
Applies to stationary or portable, single-phase or polyphase, air-cooled isolating and safety isolating transformers, associated or otherwise, having a rated supply voltage not exceeding 1000 V alternating current and 1000 V unsmoothed direct current and rated frequency not exceeding 500 Hz.
Has the status of a group safety publication in accordance with IEC Guide 104.
Transformateurs de séparation des circuits et transformateurs de sécurité. Règles
S'applique aux transformateurs de séparation des circuits et transformateurs de sécurité, incorporés ou non, à refroidissement par air, fixes ou mobiles, monophasés ou polyphasés, de tension primaire assignée ne dépassant pas 1 000 V en courant alternatif et 1 000 V en courant continu non lissé, de fréquence assignée ne dépassant pas 500 Hz.
A le statut d'une publication fondamentale…