CONTROL UNITS FOR FIRE ALARM SYSTEMS
1.1 This Standard covers requirements for control units, fire alarm systems and control unit accessories for use in accordance with the Standard for the Installation of Fire Alarm Systems, CAN/ULC-S524, in accordance with Rule 32-004(1) of C22.1, Safety Standard for Electrical Installations, Canadian Electrical Code, Part I; and the National Building Code of Canada. 1.2 This Standard also…
Éditeur :
ULC
Statut :
Annulée
Date de publication :
2011-03-31
Code(s) de l'ICS :
13.220.20; 13.320
Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for residentia...
IEC 61000-6-3:2006+A1:2010 This part of IEC 61000 for EMC emission requirements applies to electrical and electronic apparatus intended for use in residential, commercial and light-industrial environments. Emission requirements in the frequency range 0 Hz to 400 GHz are covered. No measurement needs to be performed at frequencies where no requirement is specified. This generic EMC emission…
Éditeur :
IEC
Statut :
Révisé
Date de publication :
2011-02-16
Code(s) de l'ICS :
33.100.10
Thermoplastic nonpressure piping compendium
B181.0-11 Definitions, general requirements, and methods of testing for thermoplastic nonpressure piping 1 Scope 1.1 This Standard covers thermoplastic nonpressure piping, including (a) drain, waste, and vent pipe and pipe fittings; (b) sewer and storm pipe and pipe fittings; and (c) accessories such as factory-assembled expansion joints, closet flanges, backwater valves, and cleanouts. 1.2…
Éditeur :
CSA
Statut :
Annulée
Date de publication :
2011-01-31
Code(s) de l'ICS :
23.040.50; 23.040.50
Radiation protection — Performance criteria for radiobioassay
This International Standard provides criteria for quality assurance and control, and evaluation of performance of radiobioassay service laboratories. Criteria and guidance for in vivo radiobioassay and in vitro radiobioassay are given in separate clauses. The following are within the scope of this International Standard: the accuracy of in vivo measurements of activity and quantities of…
Éditeur :
ISO
Statut :
Publié
Date de publication :
2010-09-22
Code(s) de l'ICS :
13.280
Energy performance of food service refrigerators and freezers
Preface This is the second edition of CSA C827, Energy performance of food service refrigerators and freezers. It supersedes the first edition, published in 1998. Scope 1.1 This Standard applies to commercial refrigerator, refrigerator-freezer, and freezer cabinets that are intended for storing or holding food products and other perishable merchandise. 1.2 This Standard specifies…
Éditeur :
CSA
Statut :
Annulée
Date de publication :
2010-06-30
Code(s) de l'ICS :
97.130.20
Road vehicles — Calibration fluids for diesel injection equipment
ISO 4113:2010 specifies the requirements for calibration fluids, i.e. a basic fluid and a closer value (CV) fluid, intended for testing and calibrating diesel fuel injection equipment in production, in service and in laboratories. The CV calibration fluid requires a closer tolerance range for kinematic viscosity and density, and can be specified to enhance the accuracy of the calibration setting…
Éditeur :
ISO
Statut :
Publié
Date de publication :
2010-05-20
Code(s) de l'ICS :
43.180
Passenger car tyres — Verifying tyre capabilities — Laboratory test methods
ISO 10191:2010 specifies test methods for verifying the capabilities of tyres for passenger cars. Of the test methods presented, it is possible that only some will be required depending on the type of tyre to be tested. The tests are carried out in a laboratory under controlled conditions. ISO 10191:2010 includes a strength test for assessing the capability of the tyre structure, with respect to…
Éditeur :
ISO
Statut :
Annulée
Date de publication :
2010-02-23
Code(s) de l'ICS :
83.160.10
Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity for residential, commer...
This National Standard of Canada is equivalent to International Standard CEI/IEC 61000-6-1:2005. 1 Scope and object This part of IEC 61000 for EMC immunity requirements applies to electrical and electronic apparatus intended for use in residential, commercial and light-industrial environments. Immunity requirements in the frequency range 0 Hz to 400 GHz are covered. No tests need to be…
Éditeur :
CSA
Statut :
Annulée
Date de publication :
2009-06-30
Code(s) de l'ICS :
33.100.20
Handling of waste materials in health care facilities and veterinary health care facilities
1 Scope 1.1 This Standard specifies requirements for the packaging, collection, handling, storage, and on-site treatment and disposal of waste materials within health care facilities and veterinary health care facilities. 1.2 This Standard applies to health care facilities and veterinary health care facilities. Note: This Standard may also be applied to the following: (a) medical…
Éditeur :
CSA
Statut :
Annulée
Date de publication :
2009-02-28
Code(s) de l'ICS :
11.020; 11.020
Plume scavenging in surgical, diagnostic, therapeutic, and aesthetic settings
1 Scope 1.1 This Standard applies to systems and equipment used to capture and evacuate plume. It applies to all settings where such systems and equipment are used, including, but not limited to, the following: (a) surgical facilities; (b) dental clinics; (c) medical offices; (d) veterinary facilities; (e) laboratories and other research and testing facilities; (f) cosmetic treatment facilities…
Éditeur :
CSA
Statut :
Annulée
Date de publication :
2008-12-31
Code(s) de l'ICS :
11.020; 11.020