Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-0...
IEC 61010-2-040:2015 specifies safety requirements for electrical equipment intended for sterilization, washing, and disinfection of medical materials in the medical, veterinary, pharmaceutical and laboratory fields, when used under the environmental conditions of 1.4. It has the status of a group safety publication, as specified in IEC Guide 104. This second edition cancels and replaces the…
Safety requirements for electrical equipment for measurement, control and laboratory use - Part 031:...
IEC 61010-031:2015 RLV contains both the official IEC International Standard and its Redline version. The Redline version is available in English only and provides you with a quick and easy way to compare all the changes between the official IEC Standard and its previous edition.
IEC 61010-031:2015 specifies safety requirements for hand-held and hand-manipulated probe assemblies of the types…
Safety requirements for electrical equipment for measurement, control and laboratory use - Part 031:...
IEC 61010-031:2015 specifies safety requirements for hand-held and hand-manipulated probe assemblies of the types described below, and their related accessories. These probe assemblies are for direct electrical connection between a part and electrical test and measurement equipment. They may be fixed to the equipment or be detachable accessories for the equipment. It has the status of a group…
Fire hazard testing - Part 11-20: Test flames - 500 W flame test method
IEC 60695-11-20:2015 describes a test method consisting of two small-scale laboratory test procedures which is intended to compare the burning behaviour of different materials used in electrotechnical products. Vertically oriented bar specimens or horizontally oriented plate test specimens are exposed to a small flame ignition source with a nominal thermal power of 500 W. The test method uses two…
Safety requirements for electrical equipment for measurement, control, and laboratory use — Part 2-0...
1 Scope and object
This clause of Part 1 is applicable, except as follows:
1.1.1 Equipment included in scope
Replacement:
Replace the text with the following:
This part of IEC 61010 specifies particular safety requirements for CABINET X-RAY SYSTEMS.
A CABINET X-RAY SYSTEM is a system that contains an X-ray tube installed in a cabinet which,
independently of existing architectural…
Scope
1.1
This Standard provides guidance for the safe use of lasers in health care. It applies to all procedures in health care settings where health-related lasers are used, including, but not limited to, the following:
a) health care facilities;
b) dental clinics, offices, and facilities;
c) veterinary facilities;
d) laboratories and other research facilities;
e) physician offices;
f)…
Safety requirements for electrical equipment for measurement, control, and laboratory use — Part 2-2...
1 Scope and object
This clause of Part 1 is applicable, except as follows.
1.1.1 Equipment included in scope
Replacement:
This part of IEC 61010 specifies safety requirements and related verification tests for control
equipment of the following types:
– Programmable controllers (PLC and PAC);
– the components of Distributed Control Systems (DCS);
– the components of remote I/O – systems;
–…
Radiological protection — Performance criteria for service laboratories performing biological dosime...
ISO 19238:2014 provides criteria for quality assurance and quality control, evaluation of the performance, and the accreditation of biological dosimetry by cytogenetic service laboratories.
ISO 19238:2014 addresses
a) the confidentiality of personal information, for the customer and the service laboratory,
b) the laboratory safety requirements,
c) the calibration sources and calibration…
Plume scavenging in surgical, diagnostic, therapeutic, and aesthetic settings
Scope
1.1
This Standard applies to systems and equipment used to capture and evacuate plume. It applies to all settings where such systems and equipment are used, including, but not limited to, the following:
a) surgical facilities;
b) dental clinics;
c) medical offices;
d) veterinary facilities;
e) laboratories and other research and testing facilities;
f) cosmetic…
Sound and television broadcast receivers and associated equipment -Immunity characteristics - Limits...
CISPR 20:2006+A1:2013 applies to television broadcast receivers, sound broadcast receivers and associated equipment intended for use in the residential, commercial and light industrial environment. Describes the methods of measurement and specified limits applicable to sound and television receivers and to associated equipment with regard to their immunity characteristics to disturbing signals.…