Corrosion of metals and alloys — Determination of AC corrosion — Protection criteria
ISO 18086:2015 is applicable to buried cathodically-protected pipeline that is influenced by AC traction systems and/or AC power lines.
In the presence of AC interference, the protection criteria given in ISO 15589 1 are not sufficient to demonstrate that the steel is being protected against corrosion.
ISO 18086:2015 provides limits, measurement procedures, mitigation measures, and information to…
1.1
There is a commentary available for this Clause.
This Standard covers the design, construction, operation, maintenance, deactivation, and abandonment
of oil and gas industry pipeline systems that convey
a) liquid hydrocarbons, including crude oil, multiphase fluids, condensate, liquid petroleum products,
natural gas liquids, and liquefied petroleum gas;
b) oilfield water;
c) oilfield…
Règles de sécurité pour appareils électriques de mesurage, de régulation et de laboratoire - Partie ...
L'IEC 61010-031:2015 spécifie les exigences de sécurité relatives aux sondes portatives et manipulées à la main correspondant aux types décrits ci-dessous, ainsi que leurs accessoires connexes. Ces sondes équipées sont prévues pour la connexion électrique directe entre une partie et un appareil de mesure et d'essai électrique. Elles peuvent être solidaires de l'appareil ou en être…
Ships and marine technology — Offshore wind energy — Port and marine operations
ISO 29400:2015 provides comprehensive requirements and guidance for the planning and engineering of port and marine operations, encompassing all documents and works related to such port and marine operations, e.g. the design and analysis of the components, systems, equipment and procedures required to perform port and marine operations, as well as the methods or procedures developed to carry them…
Information technology — Machine readable test data for biometric testing and reporting — Part 1: Te...
ISO/IEC 29120-1 establishes
? machine readable records for documenting the output of a biometric test,
? formats for data that ISO/IEC 19795 tests are required to report, and
? an ASN.1 syntax for test reports.
This standard specifically does not
? require, prohibit, or otherwise specify, the format of biometric samples or templates used in a test,
? require, prohibit or otherwise…
Information technology - Machine readable test data for biometric testing and reporting - Part 1: Te...
ISO/IEC 29120-1 establishes
? machine readable records for documenting the output of a biometric test,
? formats for data that ISO/IEC 19795 tests are required to report, and
? an ASN.1 syntax for test reports.
This standard specifically does not
? require, prohibit, or otherwise specify, the format of biometric samples or templates used in a test,
? require, prohibit or otherwise…
1.1
This Standard specifies the requirements for distribution (power), control, and signal cables, for use aboard marine vessels and fixed and floating offshore drilling or production platforms, that are
a)
rated up to 35 kV (AC or DC, phase-to-phase) maximum;
b)
in single or multi-conductor constructions;
c)
with or without metal armour; and
d)
with or without an overall jacket.
Cables rated up…
Fuel system components for compressed hydrogen gas powered vehicles
1.1
This Standard establishes requirements for newly produced compressed hydrogen gas fuel system components, intended for use on hydrogen gas powered vehicles as listed below:
a)
check valves;
b)
manual valves;
c)
manual container valves;
d)
automatic valves;
e)
gas injectors;
f)
pressure indicators;
g)
pressure regulator;
h)
pressure relief valves;
i)
pressure relief devices…
Règles de sécurité pour appareils électriques de mesurage, de régulation et de laboratoire - Partie ...
IEC 61010-2-101:2015 s'applique aux appareils destinés aux applications médicales de diagnostic in vitro (DIV), y compris aux appareils médicaux d'autodiagnostic DIV. Cette norme a le statut de publication groupée de sécurité, conformément au Guide 104 de l'IEC. La préparation de cette norme a été réalisée en étroite collaboration avec le groupe de travail CENELEC BTTF 88.1. Cette…
Safety requirements for secondary batteries and battery installations - Part 4: Valve-regulated lead...
IEC 62485-4:2015 applies to the safety aspects associated with the accommodation, the arrangements of circuits and the operation of secondary valve-regulated lead-acid cells and batteries in portable appliances. Requirements are specified which oblige the manufacturers of appliances and secondary batteries to prevent the misuse of batteries in the course of operation to provide protective…