Propylene for industrial use — Determination of oligomers — Gas chromatographic method
A liquid sample obtained at low temperature is vaporized and then passed through a chromatographic column which permits the separation of the oligomers. The detection is performed by flame ionization an the peaks obtained are compared with those derived from an external standard. The method is applicable to propylene having propene dimers (hexenes) contents greater than 20mg/kg and propene…
Butadiene for industrial use — Determination of active tert-butyl-catechol (TBC) (4- (1,1- dimethyle...
The active TBC in a test portion is extracted by mixing with a solution containing m-nitrophpenol (as the internal standard) and evaporating the butadiene. The TBC and m-nitrophenol are separated by high-performance liquid chromatography and detected by UV: The peak areas or peak heights are measured and the TBC content is determined by using a calibration graph. The polymerization inhibitor TBC…
Oil of cedarwood, Texas (Juniperus mexicana Schiede)
The Standard specifies the following characteristics of the oil. Appearance: Viscous liquid. Colour: Brown to reddish brown. Odour: Characteristic. Relative density at 20/20 °C: 0,952 - 0,966. Refractive index at 20 °C: 1,5050 - 1,5080. Optical rotation at 20 °C: Range from - 50 to - 32 . Miscibility with 90 % (V/V) ethanol at 20 °C: 1 : 5. Alcohols content, expressed as cedrol: 35 - 48 % (m/m).…
Iron ores — Determination of manganese content — Periodate spectrophotometric method
This second edition cancels and replaces the first edition (ISO 3886:1977), some clauses and annex A of which have been technically revised. The method is applicable to a concentration range of 0,02 to 8 % (m/m) of manganese in natural iron ores, and iron ore concentrates and agglomerates including sinter products.
Cold-reduced carbon steel strip with a maximum carbon content of 0,25 %
Applies to strip furnished to two levels of closer tolerances than cold-reduced carbon steel sheet, with specific quality, specific hardness requirements or mechanical properties, specific edge and specific finish. This product is commonly produced in thicknesses of 6 mm and under, and in widths up to 600 mm exclusive, in coils and cut lengths. Temper requirements or mechanical properties may be…
Textile glass — Yarns — Basis for a specification
Provides a basis for the establishment of technical specifications for textile glass yarns (strands, slivers, single yarns, folded yarns and cable yarns) such specifications shall contain the following items: designation, sampling, type of glass, type of size, linear density, size content, twist, moisture content, breaking strength, permissible faults, delivery and storage conditions.
Dried milk — Determination of lactic acid and lactates content — Enzymatic method
Applies to all types of dried milk. The sampling shall be made according to ISO 707. The method specified is mainly based on `Methods of enzymatic food analysis: UV-method for the determination of L-lactic acid and D-lactic acid in foodstuffs' by Boehringer Mannheim GmbH.
Steel and cast iron — Determination of vanadium content — Potentiometric titration method
This method is applicable to vanadium contents between 0.04 % (m/m) and 2 % (m/m). Specifies principle, reagents, apparatus, sampling, procedure, expression of results and test report. Annex A gives additional information on the international co-operative tests. Annex B includes the graphical representation of precision data.
Manganese ores — Determination of active oxygen content, expressed as manganese dioxide — Titrimetri...
This third edition cancels and replaces the second edition (ISO 312-1980), of which it constitutes a minor revision. Specifies principle, reagents, apparatus, sample, procedure and expression of results. A figure gives an example of apparatus.