Rechercher

Affiner les résultats
Code de la Classification internationale pour les normes (ICS)
Source
Code de l’organisme d’élaboration de normes (OEN)
Langue
Statut
Code de la Norme nationale du Canada (NNC)
Date de publication

De

à

Affichage 491 - 500 de 7883
Medical electrical equipment — Part 2-21: Particular requirements for the basic safety and essential...
Scope Replacement: This part of IEC 60601 applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of INFANT RADIANT WARMERS as defined in 201.3.204, also referred to as ME EQUIPMENT. If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only, or to ME SYSTEMS only, the title and content of that clause or subclause will say so. If that is not the case, the clause…
Éditeur :
CSA
Statut :
Norme
Date de publication :
2023-02-28
Code(s) de l'ICS :
11.040.10
Medical electrical equipment — Part 2-22: Particular requirements for basic safety and essential per...
Scope Replacement: This part of IEC 60601 applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of laser equipment for surgical, therapeutic, medical diagnostic, cosmetic or veterinary applications, intended for use on humans or animals, classified as LASER PRODUCT of CLASS 1C where the ENCLOSED LASER is of CLASS 3B or 4, or CLASS 3B, or CLASS 4. MEDICAL ELECTRICAL EQUIPMENT or MEDICAL…
Éditeur :
CSA
Statut :
Norme
Date de publication :
2023-02-28
Code(s) de l'ICS :
11.040.50; 11.040.50
Medical electrical equipment — Part 2-33: Particular requirements for the basic safety and essential...
Scope Replacement: This document applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of MAGNETIC RESONANCE (MR) EQUIPMENT and MAGNETIC RESONANCE (MR) SYSTEMS. NOTE Where ME EQUIPMENT and ME SYSTEMS are used in the clause headings, this is to be understood to indicate MR EQUIPMENT and MR SYSTEMS. This document does not cover the application of MR EQUIPMENT beyond the INTENDED USE. If a…
Éditeur :
CSA
Statut :
Norme
Date de publication :
2023-02-28
Code(s) de l'ICS :
11.040.55
Medical electrical equipment — Part 2-41: Particular requirements for the basic safety and essential...
Scope Replacement: This part of IEC 60601 applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of SURGICAL LUMINAIRES and LUMINAIRES FOR DIAGNOSIS, hereafter referred to as ME EQUIPMENT. If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only, or to ME SYSTEMS only, the title and content of that clause or subclause will say so. If that is not the case, the…
Éditeur :
CSA
Statut :
Norme
Date de publication :
2023-02-28
Code(s) de l'ICS :
11.040.20; 11.040.20
Medical electrical equipment — Part 2-50: Particular requirements for the basic safety and essential...
Scope Replacement: This part of IEC 60601 applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of INFANT PHOTOTHERAPY EQUIPMENT, as defined in 201.3.203, also referred to as ME EQUIPMENT. If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only, or to ME SYSTEMS only, the title and content of that clause or subclause will say so. If that is not the case, the…
Éditeur :
CSA
Statut :
Norme
Date de publication :
2023-02-28
Code(s) de l'ICS :
11.040.60
Medical electrical equipment — Part 2-67: Particular requirements for basic safety and essential per...
Scope IEC 60601-1:2005+AMD1:2012, 1.1 is replaced by: This document is applicable to the basic safety and essential performance of oxygen conserving equipment, hereafter referred to as ME equipment, in combination with its accessories intended to conserve supplemental oxygen by delivering gas intermittently and synchronized with the patient's inspiratory cycle, when used in the home…
Éditeur :
CSA
Statut :
Norme
Date de publication :
2023-02-28
Code(s) de l'ICS :
11.040.10
Medical electrical equipment — Part 2-69: Particular requirements for the basic safety and essential...
Scope IEC 60601-1:2005+AMD1:2012, 1.1 is replaced by: This document specifies requirements for the basic safety and essential performance of an oxygen concentrator in combination with its accessories, hereafter referred to as ME equipment, intended to increase the oxygen concentration of gas intended to be delivered to a single patient. Such oxygen concentrators are typically intended for use…
Éditeur :
CSA
Statut :
Norme
Date de publication :
2023-02-28
Code(s) de l'ICS :
11.040.10
Medical electrical equipment — Part 2-70: Particular requirements for the basic safety and essential...
Scope IEC 60601-1:2005+Amendment 1:2012, 1.1 is replaced by: This document is applicable to the basic safety and essential performance of sleep apnoea breathing therapy equipment, hereafter referred to as ME equipment, intended to alleviate the symptoms of patients who suffer from obstructive sleep apnoea by delivering a therapeutic breathing pressure to the respiratory tract of the patient…
Éditeur :
CSA
Statut :
Norme
Date de publication :
2023-02-28
Code(s) de l'ICS :
11.040.10
Medical electrical equipment — Part 2-74: Particular requirements for basic safety and essential per...
Scope Replacement: This document applies to the basic safety and essential performance of a humidifier, also hereafter referred to as ME equipment, in combination with its accessories, the combination also hereafter referred to as ME system. This document is also applicable to those accessories intended by their manufacturer to be connected to a humidifier where the characteristics of those…
Éditeur :
CSA
Statut :
Norme
Date de publication :
2023-02-28
Code(s) de l'ICS :
11.040.10
Information security, cybersecurity and privacy protection — Evaluation criteria for IT security — P...
1 Scope This document defines the required structure and content of security functional components for the purpose of security evaluation. It includes a catalogue of functional components that meets the common security functionality requirements of many IT products.
Éditeur :
CSA
Statut :
Norme
Date de publication :
2023-02-28
Code(s) de l'ICS :
35.030