Electromagnetic compatibility of multimedia equipment - Emission requirements
CISPR 32:2012 International Standard applies to multimedia equipment (MME) having a rated r.m.s. AC or DC supply voltage not exceeding 600 V. Equipment within the scope of CISPR 13 or CISPR 22 is within the scope of this publication. MME intended primarily for professional use is within the scope of this publication. The radiated emission requirements in this standard are not intended to be…
Éditeur :
IEC
Statut :
Révisé
Date de publication :
2012-01-29
Code(s) de l'ICS :
33.100.10
Corrosion of metals and alloys — Corrosivity of atmospheres — Guiding values for the corrosivity cat...
ISO 9224:2012 specifies guiding values of corrosion attack for metals and alloys exposed to natural outdoor atmospheres for exposures greater than one year. It is intended to be used in conjunction with ISO 9223. Guiding corrosion values for standard structural materials can be used for engineering calculations. The guiding corrosion values specify the technical content of each of the individual…
Éditeur :
ISO
Statut :
Publié
Date de publication :
2012-01-26
Code(s) de l'ICS :
77.060
Nanotechnologies — Characterization of multiwall carbon nanotube (MWCNT) samples
ISO/TR 10929:2012 identifies the basic properties of multiwall carbon nanotubes (MWCNTs) and the content of impurities, which characterize bulk samples of MWCNTs, and highlights the major measurement methods available to industry for the determination of these parameters. ISO/TR 10929:2012 provides a sound basis for the research, development and commercialization of these materials.
Éditeur :
ISO
Statut :
Publié
Date de publication :
2012-01-19
Code(s) de l'ICS :
07.120
Rubber compounding ingredients — Organic vulcanizing agents — Determination of organic peroxide cont...
ISO 14932:2012 specifies four methods for the determination of the content of the following groups of organic peroxides used as rubber vulcanizing agents. There are three titration methods and one using capillary gas-chromatography as given below. Titration method A for group a) peroxyketals: DTBPC: 1,1-Di(tert-butylperoxy)cyclohexane; DBPMC: 1,1-Di(tert-butylperoxy)-2-methylcyclohexane; DBPTC: 1…
Éditeur :
ISO
Statut :
Annulée
Date de publication :
2012-01-19
Code(s) de l'ICS :
83.040.20
Electrostatics - Part 4-4: Standard test methods for specific applications - Electrostatic classific...
IEC 61340-4-4:2012 specifies requirements for flexible intermediate bulk containers (FIBC) between 0,25 m3 and 3 m3 in volume, intended for use in hazardous explosive atmospheres. The explosive atmosphere may be created by the contents in the FIBC or may exist outside the FIBC. The requirements include: - classification and labelling of FIBC; - classification of inner liners; - specification of…
Éditeur :
IEC
Statut :
Révisé
Date de publication :
2012-01-17
Code(s) de l'ICS :
17.220.99; 17.220.99
Household and similar electrical appliances - Safety - Part 2-66: Particular requirements for water-...
IEC 60335-2-66:2002+A1:208+A2:2011 Deals with the safety of electric water-bed heaters and associated control units, their rated voltage being not more than 250 V, for household and similar purposes. Appliances intended to be used in hotels, are also within the scope of this standard. The contents of the corrigendum of July 2004 have been included in this copy. This publication is to be read…
Éditeur :
IEC
Statut :
Publié
Date de publication :
2012-01-17
Code(s) de l'ICS :
97.100.10
Three-digit code for designation of colour rendering and correlated colour temperature
IEC/TR 62732:2012(E) describes how to construct a three-digit code, representing a shorthand string combining the nominal general colour rendering index and the nominal correlated colour temperature. The contents of the corrigendum of December 2012 have been included in this copy.
Éditeur :
IEC
Statut :
Publié
Date de publication :
2012-01-09
Code(s) de l'ICS :
29.140.01
Medical electrical equipment — Part 2-56: Particular requirements for basic safety and essentialperf...
201.1.1 Scope Replacement: This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of a CLINICAL THERMOMETER in combination with its ACCESSORIES, hereafter referred to as ME EQUIPMENT. This standard specifies the general and technical requirements for electrical CLINICAL THERMOMETERS. This standard applies to all electrical CLINICAL THERMOMETERS that are used for…
Éditeur :
CSA
Statut :
Annulée
Date de publication :
2011-12-31
Code(s) de l'ICS :
11.040.55
Medical electrical equipment — Part 2-35: Particular requirements for the basic safety and essential...
201.1.1 * Scope Replacement: This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of HEATING DEVICES using BLANKETS, PADS or MATTRESSES in medical use, also referred to as ME EQUIPMENT. HEATING DEVICES intended to prewarm a bed are included in the scope of this International Standard. If a clause or subclause is specifically intended to be applicable to ME…
Éditeur :
CSA
Statut :
Annulée
Date de publication :
2011-12-31
Code(s) de l'ICS :
11.140
Household electric cooking appliances - Part 1: Ranges, ovens, steam ovens and grills - Methods for ...
IEC 60350-1:2011 specifies methods for measuring the performance of electric cooking ranges, ovens, steam ovens, and grills for household use. The ovens covered by this standard may be with or without microwave function. This standard defines the main performance characteristics of these appliances which are of interest to the user and specifies methods for measuring these characteristics. This…
Éditeur :
IEC
Statut :
Révisé
Date de publication :
2011-12-15
Code(s) de l'ICS :
97.040.20