Faecal sludge treatment units — Energy independent, prefabricated, community-scale, resource recover...
This document specifies requirements and test methods to ensure performance, safety, operability and maintainability of community-scale resource recovery faecal sludge treatment units (herein addressed as treatment units) that serve approximately, but not limited to, 1 000 to 100 000 people. This document applies to treatment units that:
a) primarily treat faecal sludge,
b) are able to…
Soil, treated biowaste, sludge and waste — Digestion of aqua regia soluble fractions of elements
This document specifies two methods for digestion of soil, treated biowaste, sludge and waste by the use of an aqua regia digestion.
Digestion with aqua regia will not necessarily accomplish total decomposition of the sample. The extracted analyte concentrations may not necessarily reflect the total content in the sample but represent the aqua regia soluble metals under the condition of this test…
Coal and coke — Determination of total sulfur — Eschka method
This document specifies a reference method for determining the total sulfur content of hard coal, brown coals and lignites, and coke by the Eschka method.
Leather — Chemical determination of the preservative (TCMTB, PCMC, OPP, OIT) content in leather by l...
This document specifies a test method by artificial perspiration solution aqueous extraction for the determination of the aqueous extractable content of the following preservative agents in leather by liquid chromatography:
— 2-(thiocyanomethylthio)-benzothiazole (TCMTB);
— 4-chloro-3-methylphenol (PCMC);
— 2-phenylphenol (OPP);
— 2-octylisothiazol-3(2H)-one (OIT);
This method can…
Automation systems and integration — Quality information framework (QIF) — An integrated model for m...
This document describes the general content and structure of the entire QIF information model. It describes the highest level data structures of QIF, that are expanded in Clauses 6 through 12 using data dictionaries and XML schema files. All QIF XML schema files can be found at www.qifstandards.org.
This document also describes practices for forming QIF instance files, called "documents,…
Leather — Chemical determination of the preservative (TCMTB, PCMC, OPP, OIT) content in leather by l...
This document specifies a test method by acetonitrile solvent extraction for the determination of the total content (solvent extractible) of the following preservative agents in leather by liquid chromatography:
— 2-(thiocyanomethylthio)-benzothiazole (TCMTB);
— 4-chloro-3-methylphenol (PCMC);
— 2-phenylphenol (OPP);
— 2-octylisothiazol-3(2H)-one (OIT);
This method can also be…
Fibre optic sensors - Part 4-3: Electric current measurement - Polarimetric method
IEC 61757-4-3: 2020 defines terminology, structure, and a characteristic test method of an optical current sensor using the polarimetric method. It addresses the current sensing element only and not the additional devices that are unique to each application. Generic specifications for fibre optic sensors are defined in IEC 61757. As the specifications of optical polarimetric fibre current sensors…
Nanomanufacturing - Key control characteristics - Part 6-13: Graphene-based material - Oxygen functi...
IEC TS 62607-6-13:2020 establishes a standardized method to determine the chemical key control characteristic
• oxygen functional group content on graphite oxide, graphene oxide, reduced graphene oxide and other types of functionalized graphene by
• Boehm titration method.
In this document, the measured functional groups are carboxyl groups (also in the form of their cyclic anhydrides),…
Electric motor-operated hand-held tools, transportable tools and lawn and garden machinery - Safety ...
IEC 62841-2-6:2020 Tools covered by this document include percussion hammers and rotary hammers, including rotary hammers with the capability to rotate only with the percussion system disengaged (drill only mode).
The rated voltage is not more than 250 V for single-phase a.c. or d.c. tools, and 480 V for three-phase a.c. tools.
This document does not apply to drills and impact drills.