Specifies requirements for fittings for threaded connections, used mainly for industrial purposes. Table 1 contains diagrams of types of fittings and their symbols. Tabulates the fitting dimensions (tables 2, 5, 9 to 12) with nominal sizes from DN 6 up to and including DN 100 (thread designation 1/8 to 4). Table 6 contains sockets (DN 6 to DN 150), reducing fittings are included in the tables 3,…
Road vehicles — Screened and waterproof spark-plug and its connection — Type 2
Specifies the essential dimensional characteristics of a spark-plug type used with spark ignition engines. Tabulates major, pitch, and minor diameters for plug thread and connector thread. A figure illustrates shapes and reference quantities of concern. This third edition cancels and replaces the second edition (1979).
Road vehicles — Screened and waterproof spark-plug and its connection — Type 3
Specifies the essential dimensional characteristics of a spark-plug type used with spark ignition engines. Tabulates major, pitch, and minor diameters for plug thread and connector thread. A figure illustrates shapes and reference quantities of concern. This third edition cancels and replaces the second edition (1979).
Apply only to the type of backflow preventer identified as
dual-check-valve type for use on residential supply service or
individual outlets. They also cover vacuum breakers for use on
laboratory faucets in nominal pipe size of 3/8 only, although
inlet or outlet connections, or both, may be different when so
required for special installations
Apply only to the type of backflow preventer identified as
dual-check-valve type for use on residential supply service or
individual outlets. They also cover vacuum breakers for use on
laboratory faucets in nominal pipe size of 3/8 only, although
inlet or outlet connections, or both, may be different when so
required for special installations.
1. Scope
1.1 This Standard applies to laboratory equipment intended to be connected to supply circuits with nominal system voltages of 750 V and less, for use indoors in nonhazardous locations in accordance with the Rules of the Canadian Electrical Code, Part I.
1.2 This Standard applies to equipment in which protection from electrical shock due to failure of functional insulation is…
Applies to polyethylene pipe, tubing and fittings for use in gas
mains and services including gathering, transmission, and
distribution application, which carry fuel gases containing not
more than 1% of aromatic hydrocarbons. It also applies to all
types of fittings and connections used in a 'plastic' gas pipe
system including plastic-to-metal transition fittings, plastic
fittings…
Performance and Compatibility Requirements for Telephone Sets
Contains performance and compatibility requirements for telephone
sets intended for direct tip and ring connection to Central
Office (CO) or Private Branch Exchange (PBX) lines. The
requirements are based on present telecommunications plant
characteristics at the telephone set interface. These
requirements apply to a telephone set intended for single-party
service. This standard covers…