1 Scope
1.1 Application
This Standard applies to complete, vent- (flue-) connected, or direct vent connected oil-fired warm air furnaces and unit heaters, irrespective of the heating capacity or the type of burner used. This Standard also applies to oil-fired condensing warm air furnaces.
1.2 Intent
This Standard applies to furnaces employing forced circulation of the heated air and furnaces…
1 Scope
1.1 Application
This Standard applies to
a)
complete vent (flue) -connected or direct-vent connected, oil-fired steam, and hot-water boilers that are provided with automatic control devices;
b)
oil-fired steam and hot-water condensing boilers;
c)
boilers having an input of less than 117.2 kW (400 000 Btu/h);
d)
low-pressure boilers (as defined in Clause 3) having an input of 117…
Oil-fired service water heaters for domestic hot water, space heating, and swimming pools
1 Scope
1.1 Intent
This Standard applies to complete flue-connected, oil-fired service water heaters that are provided with automatic control devices. These service water heaters may be used both for heating and for supplying of domestic hot water. They are not intended to be used as sole-source heating appliances.
1.2 Application
The requirements in this Standard apply to
a)
service water…
1 Scope
1.1 Inclusions
This Standard specifies minimum requirements for the design, installation, examination, and testing of siphonic roof drains. It includes definitions of terms and parameters involved in the design of siphonic drainage systems.
This Standard applies to roof drains designed and manufactured for installation in piping systems that are intended to operate under depressurized…
Automatic electrical controls — Part 2-5: Particular requirements for automatic electrical burner co...
Scope
Replacement:
This part of IEC 60730 applies to automatic electrical BURNER CONTROL SYSTEMS for the AUTOMATIC
CONTROL of burners for oil, gas, coal or other combustibles intended to be used
• for household and similar use,
• in shops, offices, hospitals, farms and commercial and industrial applications.
This International Standard is applicable
• to a complete BURNER CONTROL SYSTEM…
Dentistry — Stationary dental units and dental patient chairs — Part 2: Air, water, suction and wast...
This document specifies requirements and test methods for stationary dental units concerning
a) the properties of stationary dental unit connections to the compressed air supply, water supply, suction supply, and wastewater drain plumbing,
b) the materials, design, and construction of the compressed air and water system within the stationary dental unit,
c) the quality for incoming water and air…
Respiratory equipment — Particular requirements for basic safety and essential performance of infant...
This document applies to the basic safety and essential performance of an infant cardiorespiratory monitor, as defined in 3.10, hereafter also referred to as ME equipment, in combination with its accessories:
— intended for use in the home healthcare environment;
— intended for use by a lay operator;
— intended to monitor cardiorespiratory parameters in sleeping or resting children under…
High-voltage switchgear and controlgear - Part 212: Compact Equipment Assembly for Distribution Subs...
IEC 62271-212:2022 RLV contains both the official IEC International Standard and its Redline version. The Redline version is available in English only and provides you with a quick and easy way to compare all the changes between the official IEC Standard and its previous edition.
IEC 62271-212;2022 specifies the service conditions, rated characteristics, general structural requirements and…
High-voltage switchgear and controlgear - Part 212: Compact Equipment Assembly for Distribution Subs...
IEC 62271-212;2022 specifies the service conditions, rated characteristics, general structural requirements and test methods of the assemblies of the main electrical functional units of a high-voltage transformer substation, duly interconnected, for AC voltages up to and including 52 kV on the high-voltage side and service frequency 50 Hz or 60 Hz. The CEADS is cable‑connected to the high-voltage…
High-voltage switchgear and controlgear - Part 202: AC prefabricated substations for rated voltages ...
IEC 62271-202:2022 specifies the service conditions, rated characteristics, general structural requirements and test methods of enclosed high-voltage prefabricated substations. These prefabricated substations are cable-connected to AC high-voltage networks with an operating voltage up to and including 52 kV and power frequencies up to and including 60 Hz. They can be manually operated from inside…