Medical suction equipment — Part 3: Suction equipment powered from a vacuum or positive pressure gas...
This part of ISO 10079 specifies safety and performance requirements for medical suction equipment
powered from a vacuum or positive pressure gas source generating venturi suction. It applies to
equipment connected to medical gas pipeline systems or cylinders and venturi attachments. Annex D
illustrates the three parts of ISO 10079 by providing a schematic for typical systems.
The equipment can…
1 Scope
1.1
This Standard applies to expandable sleeving rated at 90°C, 105°C, 125°C, 150°C and 200°C for bundling
of insulated wires and cables, intended for the use in equipment designed to be installed and used in
accordance with the rules of the Canadian Electrical Code, Part I (CE Code). The product consists of an
open weave design of polymeric monofilaments.
1.2
This Standard does not apply…
Power losses in voltage sourced converter (VSC) valves for high-voltage direct current (HVDC) system...
IEC 62751-2:2014 gives the detailed method to be adopted for calculating the power losses in the valves for an HVDC system based on the "modular multi-level converter", where each valve in the converter consists of a number of self-contained, two-terminal controllable voltage sources connected in series. It is applicable both for the cases where each modular cell uses only a single turn…
Utility connections in port - Part 3: Low Voltage Shore Connection (LVSC) Systems - General requirem...
IEC PAS 80005-3:2014(E) describes low voltage shore connection (LVSC) systems, on board the ship and on shore, to supply the ship with electrical power from shore. This PAS is applicable to the design, installation and testing of LVSC systems and addresses:
- LV shore distribution systems;
- shore-to-ship connection and interface equipment;
- transformers/reactors;
- semiconductor/rotating…
Fire detection and alarm systems — Part 28: Fire protection control equipment
ISO 7240-28:2014 specifies requirements, methods of test, and performance criteria for fire protection control equipment (FPCE) connected to automatic fire protection equipment (AFPE) installed in buildings.
The FPCE receives signals from fire detection control and indicating equipment, sends control signals to, and indicates the condition of, the AFPE. The control signals are used to initiate…
Industrial communication networks - Fieldbus specifications - Part 6-2: Application layer protocol s...
IEC 61158-6-2:2014 defines the protocol provided to define the wire-representation of the service primitives defined in IEC 61158-5-2, and define the externally visible behavior associated with their transfer. This standard specifies the protocol of the Type 2 fieldbus application layer, in conformance with the OSI Basic Reference Model (ISO/IEC 7498-1) and the OSI application layer structure (…
Réseaux de communication industriels - Spécifications des bus de terrain - Partie 6-2: Spécification...
L'IEC 61158-6-2:2014 décrit le protocole mis en place pour définir la représentation filaire des primitives de service définies dans la CEI 61158-5-2 et définir le comportement visible de l'extérieur associé à leur transfert. La présente norme spécifie le protocole de la couche application de bus de terrain de Type 2, en conformité avec le modèle de référence de base OSI (ISO/CEI 7498-1…
Industrial communication networks - Fieldbus specifications - Part 6-10: Application layer protocol ...
IEC 61158-6-10:2014 defines the protocol provided to define the wire-representation of the service primitives defined in IEC 61158-5-10, and define the externally visible behavior associated with their transfer. This standard specifies the protocol of the Type 10 fieldbus application layer, in conformance with the OSI Basic Reference Model (ISO/IEC 7498-1) and the OSI application layer structure…
Industrial communication networks - Fieldbus specifications - Part 6-19: Application layer protocol ...
IEC 61158-6-19:2014 defines the protocol provided to define the FAL user at the boundary between the user and the Application Layer of the Fieldbus Reference Model, and Systems Management at the boundary between the Application Layer and Systems Management of the Fieldbus Reference Model. This standard specifies the structure and services of the IEC fieldbus Application Layer, in conformance with…
Industrial communication networks - Fieldbus specifications - Part 5-2: Application layer service de...
IEC 61158-5-2:2014 defines the services provided to the FAL user at the boundary between the user and the application layer of the fieldbus reference model, and Systems Management at the boundary between the application layer and Systems Management of the fieldbus reference model. This standard specifies the structure and services of the Type 2 fieldbus application layer, in conformance with the…