Information technology - UPnP Device Architecture - Part 12-10: Remote User Interface Device Control...
This service definition is compliant with the UPnP Device Architecture version 1.0.
This service-type encapsulates the management of an out-of-band remoting protocol connection to a device capable of user interaction. This service is required for all Remote UI clients.
It is specified in: urn:schemas-upnp-org:device:RemoteUIClientDevice
Series capacitors for power systems - Part 3: Internal fuses
IEC 60143-3:2015 applies to internal fuses designed to isolate faulty capacitor elements, to allow operation of the remaining parts of that capacitor unit and the bank in which the capacitor unit is connected. Such fuses are not a substitute for a switching device such as a circuit-breaker, or for external protection of the capacitor bank, or any part thereof. The object of this part of IEC 60143…
Road vehicles — Vehicle test methods for electrical disturbances from narrowband radiated electromag...
ISO 11451-3:2015 specifies methods for testing the immunity of passenger cars and commercial vehicles to electromagnetic disturbances from on-board transmitters connected to an external antenna and portable transmitters with integral antennas, regardless of the vehicle propulsion system (e.g. spark ignition engine, diesel engine, electric motor).
Live working – Phase comparators – Part 1: Capacitive type to be used for voltages exceeding 1 kV a....
1 Scope
This part of IEC 61481 is applicable to portable phase comparators of capacitive type to be
used on electrical systems for voltages exceeding 1 kV a.c. and frequencies of 50 Hz and/or
60 Hz.
This standard is applicable to:
?? single-pole phase comparators of capacitive type operating with a memory system up to
36 kV a.c.,
?? two-pole phase comparators of capacitive type operating with a…
1.1
Cette norme s’applique à la conception, à l’installation, au fonctionnement, à l’entretien et à la mise à
l’essai de l’appareillage dont le rôle est d’assurer l’alimentation électrique de secours :
a) dans des bâtiments ou des installations en cas de panne de l’alimentation normale, lorsqu’une
alimentation électrique de secours est exigée dans le Code national du bâtiment du Canada
(CNBC…
1 Scope
1.1
This Standard applies to hydromassage bathtub appliances and associated accessories for residential and commercial use that are intended to be permanently connected to a plumbing system and building structure, for use indoors in non-hazardous locations, permanently installed in accordance with the Rules of the Canadian Electrical Code, Part I, and either
a)
permanently connected…
1.1 The requirements in this standard cover sealed wire connector systems, including insulating caps,
covers, resins, tubing, and tapes provided with, or for use with, specific wire connectors. These systems
are intended for wet or damp locations, and other installations such as direct burial, below grade, or above
grade where protected from direct exposure to sunlight. The wire connectors…
1.1
This Standard applies to exit signs, unit equipment, emergency luminaires, and central power systems intended for connection to circuits with nominal voltages of 600 V and less and providing illumination in the event of a failure of the normal power supply for nonhazardous locations in accordance with the Rules of the Canadian Electrical Code, Part I.
1.2
This Standard includes…
Industrial valves — Measurement, test and qualification procedures for fugitive emissions — Part 1: ...
ISO 15848-1:2015 specifies testing procedures for evaluation of external leakage of valve stem seals (or shaft) and body joints of isolating valves and control valves intended for application in volatile air pollutants and hazardous fluids. End connection joints, vacuum application, effects of corrosion, and radiation are excluded from this part of ISO 15848.
ISO 15848-1:2015 concerns…