Personal Flotation Devices – Part 4: Lifejackets, Performance Level 100 –Safety Requirements
1 Scope This part of ISO 12402 specifies the safety requirements for lifejackets, performance level 100. It applies to lifejackets used by adults or children. 1DV DT Modification by revising the second sentence of clause 1 to add infants, as follows: It applies to lifejackets used by adults, children, or infants. 1DV.1 DR Addition to clause 1 as follows: 1DV.1.1 Where references are made…
Éditeur :
UL
Statut :
Norme
Date de publication :
2020-07-08
Code(s) de l'ICS :
13.340.70
Building information modelling (BIM) — Data templates for construction objects used in the life cycl...
This document sets out the principles and structure for data templates for construction objects. It is developed to support digital processes using machine-readable formats using a standard data structure to exchange information about any type of construction object, e.g. product, system, assembly, space, building etc., used in the inception, brief, design, production, operation and demolition of…
Éditeur :
ISO
Statut :
Publié
Date de publication :
2020-07-05
Code(s) de l'ICS :
91.010.01; 35.240.67
Air cargo unit load devices — Performance requirements and test parameters
This document specifies the minimum requirements for airworthiness approval of air cargo pallets, nets and containers, generally designated as air cargo unit load devices (ULD). This document is intended to provide a uniform technical reference for air cargo unit load devices approval. As a prerequisite, it is presupposed that the applicable general civil aviation requirements and the aircraft…
Éditeur :
ISO
Statut :
Publié
Date de publication :
2020-06-29
Code(s) de l'ICS :
49.100; 49.120
STANDARD FOR SINGLE AND MULTIPLE STATION CARBON MONOXIDE ALARMS FOR NON-RESIDENTIAL APPLICATIONS
alarms intended for protection in non-residential or ordinary (nonhazardous) areas. 1.2 Carbon monoxide alarms covered by these requirements are intended to respond to the presence of carbon monoxide from sources such as, but not limited to, exhaust from internal-combustion engines, abnormal operation of fuel-fired appliances, and fireplaces. Carbon monoxide alarms are intended to alarm at…
Éditeur :
ULC
Statut :
Norme
Date de publication :
2020-06-29
Code(s) de l'ICS :
13.320; 91.120
Measurement of radioactivity — Alpha-, beta- and photon emitting radionuclides — Reference measureme...
This document specifies the characteristics of reference measurement standards of radioactive surface contamination, traceable to national measurement standards, for the calibration of surface contamination monitors. This document relates to alpha-emitters, beta-emitters, and photon emitters of maximum photon energy not greater than 1,5 MeV. It does not describe the procedures involved in the use…
Éditeur :
ISO
Statut :
Publié
Date de publication :
2020-06-21
Code(s) de l'ICS :
17.240
Guidelines for in-service inspections for primary coolant circuit components of light water reactors...
This document gives guidelines for pre-service inspections (PSI) and in-service inspections (ISI) of the surfaces using the magnetic particle testing and penetrant testing on components of the reactor coolant circuit of light water reactors. This document is also applicable to other components of nuclear installations. Test systems for the localisation of surface inhomogeneities and requirements…
Éditeur :
ISO
Statut :
Publié
Date de publication :
2020-06-11
Code(s) de l'ICS :
27.120.10
Guidelines for in-service inspections for primary coolant circuit components of light water reactors...
This document gives guidelines for pre-service-inspections (PSI) and in-service inspections (ISI) with mechanized ultrasonic test (UT) devices on components of the reactor coolant circuit of light water reactors. This document is also applicable on other components of nuclear installations. Mechanized ultrasonic inspections are carried out in order to enable an evaluation in case of — fault…
Éditeur :
ISO
Statut :
Publié
Date de publication :
2020-06-11
Code(s) de l'ICS :
27.120.10
Guidelines for in-service inspections for primary coolant circuit components of light water reactors...
This document gives guidelines for pre-service inspection (PSI) and in-service inspections (ISI) for reactor coolant circuit components of light water reactors and their installations as direct or remote visual testing in the form of a — general visual testing (overview), or — selective visual testing (specific properties). This document is also applicable to other components of nuclear…
Éditeur :
ISO
Statut :
Publié
Date de publication :
2020-06-11
Code(s) de l'ICS :
27.120.10
Household and similar electrical appliances - Safety - Part 2-81: Particular requirements for foot w...
IEC 60335-2-81:2015+A1:2017+A2:2020 deals with the safety of electric foot warmers and heating mats for household and similar purposes, their rated voltage being not more than 250 V. Appliances not intended for normal household use but which nevertheless may be a source of danger to the public, such as appliances intended to be used by laymen in shops, in light industry and on farms, are within…
Éditeur :
IEC
Statut :
Révisé
Date de publication :
2020-06-07
Code(s) de l'ICS :
13.120; 97.100.10
Household and similar electrical appliances - Safety - Part 2-82: Particular requirements for amusem...
IEC 60335-2-82:2017+A1:2020 deals with the safety of electric commercial amusement machines and personal service machines, their rated voltage being not more than 250 V for single-phase appliances and 480 V for other appliances. Examples of appliances that are within the scope of this standard are: - amusement machines; - tables; - bowling machines; - dartboards; - driving simulators; -…
Éditeur :
IEC
Statut :
Révisé
Date de publication :
2020-06-03
Code(s) de l'ICS :
97.180; 97.200.40