Energy performance of buildings — Calculation of energy use for space heating and cooling
ISO 13790:2008 gives calculation methods for assessment of the annual energy use for space heating and cooling of a residential or a non-residential building, or a part of it, referred to as “the building”.
This method includes the calculation of:
the heat transfer by transmission and ventilation of the building zone when heated or cooled to constant internal temperature…
Preface
This is the harmonized ANCE, CSA, and UL Standard for Thermoplastic-Insulated Wires and Cables. It is the fourth edition of NMX-J-010-ANCE, the ninth edition of CSA-C22.2 No. 75, and the fourteenth edition of UL 83. This edition of CSA-C22.2 No. 75 supersedes the previous edition published in 2003. This edition of UL 83 supersedes the previous edition published in 2003.
1 Scope
1.1…
Quality management - Customer satisfaction - Guidelines for dispute resolution external to organizat...
This National Standard of Canada is equivalent to International Standard ISO 10003:2007.
1 Scope
This International Standard provides guidance for an organization to plan, design, develop, operate, maintain
and improve an effective and efficient dispute-resolution process for complaints that have not been resolved
by the organization. This International Standard is applicable to:
-…
Conduits métalliques rigides en acier pour canalisations électriques
1 Domaine d'application
1.1
Cette norme s'applique aux conduits métalliques rigides en acier (ERMC-S) ainsi qu'à leurs coudes,
raccords et mamelons, destinés à la fabrication des canalisations métalliques pour fils et câbles
conformément à la CSA C22.1, Code canadien de l'électricité, Première partie, à la NOM-001-SEDE, Standard
for Electrical Installations et à la NFPA…
Medical Electrical Equipment - Part 1: General Requirements for Basic Safety and Essential Performan...
This National Standard of Canada is based on International Standard IEC 60601-1:2005.
1.1 * Scope
This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of MEDICAL ELECTRICAL EQUIPMENT and MEDICAL ELECTRICAL SYSTEMS, hereafter referred to as ME EQUIPMENT and ME SYSTEMS.
If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only, or to ME…
Medical Electrical Equipment - Part 2-2: Particular Requirements for the Safety of High Frequency Su...
This National Standard of Canada is equivalent to International Standard CEI/IEC 60601-2-2:2006.
1 Scope and object
This clause of the General Standard applies except as follows:
*1.1 Scope
Addition:
This Particular Standard specifies requirements for the safety of HIGH FREQUENCY SURGICAL EQUIPMENT and HF SURGICAL ACCESSORIES used in medical practice, as defined in 2.1.110 and…
Thermal-Links - Requirements and Application Guide
This National Standard of Canada is based on International Standard CEI/IEC 60691:2002+Amendment 1:2006.
1 Scope and object
This International Standard is applicable to thermal-links intended for incorporation in electrical appliances, electronic equipment and component parts thereof, normally intended for use indoors, in order to protect them against excessive temperatures under abnormal…
Textile Test Methods
Textiles - Fabrics - Determination of Width and Length
This National Standard of Canada is identical to International Standard ISO 22198:2006.
1 Scope
This International Standard specifies a method for the determination of length and width of textile fabrics that are
in a tension-free relaxed state. The test is applicable to textile fabrics of full width, folded lengthwise down the
middle, or in tubular form, but no longer than 100 m. This…
Lung Ventilators for Medical Use - Particular Requirements for Basic Safety and Essential Performanc...
This National Standard of Canada is based on International Standard ISO 10651-5:2006.
1 Scope
This part of ISO 10651 specifies the basic safety and essential performance requirements for gas-powered emergency resuscitators (3.10) intended for use with humans by first responders. This equipment is intended for emergency field use and is intended to be continuously operator attended in normal use…
Transportable Liquid Oxygen Systems for Medical Use - Particular Requirements
This National Standard of Canada is based on International Standard ISO 18777:2005.
1 Scope
IEC 60601-1:1988, Clause 1, applies except as follows:
Amendments (add at end of 1.1):
1.1
This International Standard specifies requirements for the safety and essential performance of transportable liquid oxygen systems which are used as a supply source for oxygen therapy. These devices usually consist…