1 General
1.1 Scope
1.1.1 This Standard applies to low-voltage fuses rated 1000 V or less, AC and/or DC, with interrupting
ratings up to 200 kA. These fuses are intended to be used in accordance with the Canadian Electrical
Code, Part I (CEC), and the National Electrical Code, NFPA 70 (NEC).
1.2 Object
1.2.1 This Standard and its subsequent Parts establish the characteristics,…
Electric motors and generators for use in hazardous (classified) locations
1 Scope
1.1 This standard applies to electric motors and generators or submersible and nonsubmersible sewage
pumps and systems suitable for use in Class I, Division 1, Groups B, C and D, and Class II, Division 1,
Groups E, F and G, hazardous (classified) locations as defined by the Canadian Electrical Code, C22.1
Part I (CEC), and the National Electrical Code, ANSI/NFPA 70 (NEC).
1.2…
Household and similar electrical appliances - Safety - Part 2-53: Particular requirements for sauna ...
IEC 60335-2-53:2011 deals with the safety of electric sauna heating appliances and infrared emitting units having a rated power input not exceeding 20 kW, their rated voltage being not more than 250 V for single-phase appliances and 480 V for other appliances. The appliances covered by this standard are intended for use in the home and in public saunas located in blocks of flats, hotels and…
Effluent monitoring programs at Class I nuclear facilities and uranium mines and mills
1 Scope
1.1 Facilities
1.1.1 Types of facilities
1.1.1.1
This Standard addresses the design and operation of effluent monitoring programs for Class I nuclear
facilities and uranium mines and mills. These facilities include
(a) nuclear reactors;
(b) uranium mines, mills, refineries, and conversion plants;
(c) uranium fuel fabrication plants;
(d) isotope processing facilities;
(e…
1 Scope
1.1 These requirements cover humidifiers rated 600 V or less, and intended to be used in accordance
with the National Electrical Code (NEC), ANSI/NFPA 70, and the Rules of the Canadian Electrical Code
(CEC), Part I, C22.1.
1.2 These requirements cover humidifiers intended for residential and commercial use. This includes
humidifiers of the centrifugal atomizing type, evaporative-…
1 Scope
This National Standard of Canada specifies the manufacturing, performance and labelling requirements for
remanufactured toner cartridges for monochrome laser print devices, including but not limited to printers, multifunction
devices, copiers and facsimile (fax) machines.
Note: Some cartridges, because of their original OEM design and construction, may be more suitable than others for…
1 Scope
This standard applies to the design, colour, materials, construction and performance requirements of the National
Flag of Canada intended for outdoor use.
The testing and evaluation of a product against this standard may require the use of materials and equipment
that could be hazardous. This standard does not purport to address all the safety aspects associated with its use.…
1 Scope
This standard applies to the design, colour, materials, construction and performance requirements of the National
Flag of Canada intended for indoor use.
The testing and evaluation of a product against this standard may require the use of materials and equipment
that could be hazardous. This standard does not purport to address all the safety aspects associated with its use.…
1.1 This Standard covers requirements for control units, fire alarm systems and control unit accessories
for use in accordance with the Standard for the Installation of Fire Alarm Systems, CAN/ULC-S524, in
accordance with Rule 32-004(1) of C22.1, Safety Standard for Electrical Installations, Canadian Electrical
Code, Part I; and the National Building Code of Canada.
1.2 This Standard also…
Low-voltage surge protective devices - Part 11: Surge protective devices connected to low-voltage po...
IEC 61643-11:2011 is applicable to devices for surge protection against indirect and direct effects of lightning or other transient overvoltages. These devices are packaged to be connected to 50/60 Hz a.c. power circuits, and equipment rated up to 1 000 V r.m.s. Performance characteristics, standard methods for testing and ratings are established. These devices contain at least one nonlinear…