Secondary cells and batteries containing alkaline or other non-acid electrolytes — Portable sealed r...
This is the first edition of CAN/CSA-E61951-2, Secondary cells and batteries containing alkaline or other
non-acid electrolytes — Portable sealed rechargeable single cells — Part 2: Nickel-metal hydride, which
is an adoption, with Canadian deviations, of the identically titled IEC (International Electrotechnical
Commission) Standard 61951-2 (third edition, 2011-05).
For brevity, this Standard…
Secondary cells and batteries containing alkaline or other non-acid electrolytes —Portable sealed re...
This is the first edition of CAN/CSA-E61951-1, Secondary cells and batteries containing alkaline or other
non-acid electrolytes — Portable sealed rechargeable single cells — Part 1: Nickel-cadmium, which is an
adoption, with Canadian deviations, of the identically titled IEC (International Electrotechnical
Commission) Standard 61951-1 (third edition, 2013-10).
For brevity, this Standard will…
Équipements des technologies de l’audio/vidéo, de l’information et de la communication —Partie 1 : E...
Ce document constitue la norme harmonisée au Groupe CSA et aux UL visant les équipements des
technologies de l’audio/vidéo, de l’information et de la communication — Partie 1 : Exigences de sécurité. Il
s’agit de la deuxième édition de la CAN/CSA-C22.2 nº 62368-1 et de la deuxième édition de l’UL 62368-1.
Cette édition de la CAN/CSA-C22.2 nº 62368-1 remplace l’édition précédente publiée en…
Safety requirements for electrical equipment for measurement, control, and laboratory use — Part 2-0...
This is the third edition of C22.2 No. 61010-2-032, Safety requirements for electrical equipment for
measurement, control, and laboratory use — Part 2-032: Particular requirements for hand-held and handmanipulated
current sensors for electrical test and measurement, which is an adoption, with Canadian
deviations, of the identically titled IEC (International Electrotechnical Commission)…
Interpreting — Guidelines for community interpreting
ISO 13611:2014 establishes criteria and recommendations for community interpreting during oral and signed communication that enables access to services for people who have limited proficiency in the language of such services. Community interpreting occurs in a wide variety of private and public settings and supports equal access to community and/or public services.
ISO 13611:2014 addresses…
Wireless sensor networks (WSN) are generating increasing interest from industry and research. This is driven by the availability of inexpensive, low-powered miniature components such as processors, radios and sensors which are sometimes integrated on a single chip.
The idea of the Internet of Things (IoT) developed in parallel to WSNs. While IoT doesn’t assume a specific communication…
STANDARD METHOD OF FIRE TESTS FOR NON-METALLIC ELECTRICAL AND OPTICAL FIBRE CABLE RACEWAY SYSTEMS
1 SCOPE
1.1 The requirements in this Standard apply to non-metallic raceway systems used to enclose optical
fibre cables, communication cables and electrical wires and cables with combustible insulation and jackets
that are rated FT4 and higher designed for use in accordance with CSA C22.1, Canadian Electrical Code,
Part 1, Safety Standard for Electrical Installations, and the National…
1 Scope
1.1 This standard applies to quick-connect terminals, both connectors and tabs, having nominal widths of
2.8, 3.2, 4.8, 5.2, and 6.3 mm (0.110, 0.125, 0.187, 0.205, and 0.250 in). They are intended for internal
wiring connections in electrical equipment and for the field termination of conductors to electrical
equipment in accordance with Part I of the Canadian Electrical Code, C22.1…
Fixed capacitors for use in electronic equipment — Part 14: Sectional specification — Fixed capacito...
Canadian deviations
International Standard IEC 60384-14:2013 (fourth edition) forms the basis for CAN/CSA-E60384-14, which
contains the following deviations in addition to those shown in CAN/CSA-E60384-1:14.
[Replace all references to “IEC 60384-1” with “CAN/CSA-E60384-1”]
1 General
1.1 Scope
[Add the following]
This Standard covers the above-noted products that are intended to be…
STANDARD FOR ABOVEGROUND STEEL TANKS FOR FUEL OIL AND LUBRICATING OIL
SCOPE
1.1 This Standard covers the design and construction of aboveground steel non-pressure tanks intended
for installation inside or outside buildings and for the storage of:
A Combustible liquid intended to be used as heating fuel and/or generator fuel; and
B Lubricating oil.
NOTE 1: These tanks may also be used for the storage of used oil as a heating and/or generator fuel. For tanks…