Plugs, receptacles, and cable connectors of the pin and sleeve type (Bi-national standard, with UL 1...
Scope
1.1
This standard applies to pin and sleeve type plugs, receptacles, power inlets, and connectors, rated up to 800 amperes and up to 600 volts ac or dc, and which may include up to eight pilot contacts. These devices are intended to provide power from branch circuits, or are for direct connection to the branch circuit in accordance with the Canadian Electrical Code Part I (CEC), C22.1, and…
1 Scope
This National Standard of Canada applies to automotive fuel composed of 50 to 85% by volume denatured fuel
ethanol and gasoline strictly for use in flexible fuel vehicles over a wide range of climatic conditions.
Fuel produced to this standard is not for use in conventional vehicles designed to operate on gasoline containing
up to 10% by volume ethanol.
Precautions for the use of…
1 SCOPE
1.1 These requirements apply to materials for the fabrication of air duct systems for use in accordance
with the requirements in the National Building Code of Canada. The materials covered by these
requirements include preformed lengths of flexible or rigid ducts, materials in the form of boards for field
fabrication of lengths of rigid ducts, and preformed flexible connectors.
Low-voltage switchgear and controlgear — Part 1: General rules
This standard applies, when required by the relevant product standard, to switchgear and controlgear
hereinafter referred to as ²equipment² and intended to be connected to circuits, the rated voltage of which
does not exceed 1 000 V a.c. or 1 500 V d.c.
It does not apply to low-voltage switchgear and controlgear assemblies which are dealt with in IEC 60439.
NOTE – In certain clauses or…
Scope
1.1 These requirements cover FITTINGS for use with cable and conduit intended for installation in accordance with the National Electrical Code, ANSI/NFPA 70, the Canadian Electrical Code (CEC), Part I, CSA C22.1, and the Standard for Electrical Installations, NOM-001-SEDE.
1.2 These requirements cover CONDUIT LOCKNUTS, conduit BUSHINGS, metal stud BUSHINGS, CONDUIT BODIES, and entrance…
Research ethics oversight of biomedical clinical trials
1 Scope
This National Standard of Canada applies to Research Ethics Boards (REBs) that evaluate applications for
ethical acceptability. If an REB grants ethics approval to conduct biomedical clinical trials, it will provide research
ethics oversight of biomedical clinical trials that are subject to the Food and Drugs Act and applicable Regulations
(see 2.1).
This Standard does not preclude…
Non-recirculating direct gas-fired industrial air heaters
Scope
1.1
This standard applies to newly produced, direct gas-fired industrial air heaters of the non-recirculating type, hereinafter referred to as heaters, whose purpose is to offset building heat loss. All air to the heater shall be ducted directly from outdoors and the products of combustion generated by the heater are released into the air stream being heated.
Heaters covered by this…
Grounding and bonding equipment (Tri-national standard, with NMX-J-590-ANCE and UL 467)
Scope
1.1 This Standard applies to grounding and bonding equipment for use in accordance with the Canadian Electrical Code, Part I, CSA C22.1, in Canada, the National Electrical Code, NFPA 70, in the United States, or the Standard for Electrical Installations, NOM-001-SEDE, in Mexico.
1.2 This Standard applies to the following grounding and bonding equipment:
a) ground clamps, bonding…
Safety of Household and Similar Electrical Appliances — Part 2-34:Particular Requirements for Motor-...
1 Scope
This clause of Part 1 is replaced by the following.
This International Standard deals with the safety of sealed (hermetic and semi-hermetic type) motorcompressors,
their protection and control systems, if any, which are intended for use in equipment for
household and similar purposes and which conform with the standards applicable to such equipment. It
applies to motor-…
Standard for Suspended Ceiling Grid Low Voltage Systems and Equipment
1.1 These requirements cover suspended ceiling grid low voltage systems and equipment intended for
installation and use in accordance with the:
In Canada:
Canadian Electrical Code, Part I, Safety Standard for Electrical Installations, CSA
C22.1,
In the United States:
National Electrical Code (NEC), ANSI/NFPA 70.
1.2 The suspended ceiling grid low voltage systems covered by this standard…