1.1
This Standard applies to newly produced, direct gas-fired process air heaters of the recirculating or non- recirculating type (see Clause 3, Definitions), hereinafter referred to as heaters, whose primary purpose is to provide process heating to non-occupied spaces within commercial and industrial buildings and may also include operation as a non-recirculating ventilation air heater (see…
Non-recirculating direct gas-fired heating and forced ventilation appliances for commercial and indu...
1.1
This Standard applies to newly produced, non-recirculating direct gas-fired heating and forced ventilation appliances, hereinafter referred to as heaters, whose purpose is to address building infiltration, replace building air that is exhausted, offset building conduction heat loss and provide outside air ventilation. All air to the heater is ducted directly from outdoors and the products of…
STANDARD FOR EXTERNAL CORROSION PROTECTION SYSTEMS FOR STEEL UNDERGROUND TANKS FOR FLAMMABLE AND COM...
1.1 This Standard covers requirements for external corrosion protection systems on steel non-pressure
tanks that are used for the underground storage of flammable liquids and combustible liquids. The
requirements are structured as follows:
A Section 5, Cathodically Protected Tanks, covers external corrosion protection using sacrificial
magnesium and zinc anodes, low profile nylon isolating…
This National Standard of Canada applies to glazing materials that have been subjected to the test methods
described herein. Such test methods are intended to demonstrate minimum performance characteristics designed
to reduce the likelihood of cutting and piercing injuries resulting when glazing materials used in areas of human
impact (see Annex A) in building and architectural applications…
Plugs, receptacles, and cable connectors of the pin and sleeve type
1.1 This standard applies to pin and sleeve type plugs, receptacles, power inlets, and connectors, rated
up to 800 amperes and up to 600 volts ac or dc, and which may include up to eight pilot contacts. These
devices are intended to provide power from branch circuits, or are for direct connection to the branch
circuit in accordance with the Canadian Electrical Code Part I, the National…
STANDARD FOR HALOCARBON CLEAN AGENT FIRE EXTINGUISHERS
1.1 These requirements cover the construction and performance, exclusive of performance during fire
tests, of portable halocarbon clean agent fire extinguishers. Halocarbon clean agent fire extinguishers are
intended to be utilized in accordance with the Standard for Portable Fire Extinguishers, NFPA 10 and with
the National Fire Code of Canada.
1.2 The requirements for performance during…
NORME SUR LES EXTINCTEURS AUX AGENTS PROPRES À L’HALOCARBURE
1.1 Ces exigences visent la construction et le fonctionnement des extincteurs portatifs aux agents
propres à l’halocarbure. Elles ne visent toutefois pas le fonctionnement au cours des essais de réaction
au feu. Les extincteurs aux agents propres à l’halocarbure sont destinés à être utilisés conformément à
la Standard for Portable Fire Extinguishers, NFPA 10 et au Code national de prévention…
1.1
This Standard applies to newly produced vented gas-fired space heating appliances (see Clause 3,
Definitions), hereinafter referred to as appliance(s), constructed entirely of new, unused parts and
materials, and having input ratings up to and including 400,000 Btu/hr (117 228 W).
These appliances are for use with:
a) natural gas;
b) manufactured gas;
c) mixed gas;
d) propane gas […
Low-voltage switchgear and controlgear — Part 7-1: Ancillary equipment — Terminal blocks for copper ...
This part of IEC 60947 specifies requirements for terminal blocks with screw-type or screw-less-type
clamping units primarily intended for industrial or similar use and to be fixed to a support to provide
electrical and mechanical connection between copper conductors. It applies to terminal blocks intended to
connect round copper conductors, with or without special preparation, having a cross-…
Low-voltage switchgear and controlgear — Part 7-2: Ancillary equipment — Protective conductor termin...
This part of IEC 60947 specifies requirements for protective conductor terminal blocks with PE function
up to 120 mm2 (250 kcmil) and for protective conductor terminal blocks with PEN function equal to and
above 10 mm2 (AWG 8) with screw-type or screwless-type clamping units, primarily intended for industrial
applications.
NOTE: AWG is the abbreviation of “American Wire Gage” [Gage (US) = Gauge (…