Plugs, receptacles, and cable connectors of the pin and sleeve type
1.1 This standard applies to pin and sleeve type plugs, receptacles, power inlets, and connectors, rated
up to 800 amperes and up to 600 volts ac or dc, and which may include up to eight pilot contacts. These
devices are intended to provide power from branch circuits, or are for direct connection to the branch
circuit in accordance with the Canadian Electrical Code Part I, the National…
STANDARD FOR HALOCARBON CLEAN AGENT FIRE EXTINGUISHERS
1.1 These requirements cover the construction and performance, exclusive of performance during fire
tests, of portable halocarbon clean agent fire extinguishers. Halocarbon clean agent fire extinguishers are
intended to be utilized in accordance with the Standard for Portable Fire Extinguishers, NFPA 10 and with
the National Fire Code of Canada.
1.2 The requirements for performance during…
NORME SUR LES EXTINCTEURS AUX AGENTS PROPRES À L’HALOCARBURE
1.1 Ces exigences visent la construction et le fonctionnement des extincteurs portatifs aux agents
propres à l’halocarbure. Elles ne visent toutefois pas le fonctionnement au cours des essais de réaction
au feu. Les extincteurs aux agents propres à l’halocarbure sont destinés à être utilisés conformément à
la Standard for Portable Fire Extinguishers, NFPA 10 et au Code national de prévention…
1.1
This Standard applies to newly produced vented gas-fired space heating appliances (see Clause 3,
Definitions), hereinafter referred to as appliance(s), constructed entirely of new, unused parts and
materials, and having input ratings up to and including 400,000 Btu/hr (117 228 W).
These appliances are for use with:
a) natural gas;
b) manufactured gas;
c) mixed gas;
d) propane gas […
Low-voltage switchgear and controlgear — Part 7-1: Ancillary equipment — Terminal blocks for copper ...
This part of IEC 60947 specifies requirements for terminal blocks with screw-type or screw-less-type
clamping units primarily intended for industrial or similar use and to be fixed to a support to provide
electrical and mechanical connection between copper conductors. It applies to terminal blocks intended to
connect round copper conductors, with or without special preparation, having a cross-…
Low-voltage switchgear and controlgear — Part 7-2: Ancillary equipment — Protective conductor termin...
This part of IEC 60947 specifies requirements for protective conductor terminal blocks with PE function
up to 120 mm2 (250 kcmil) and for protective conductor terminal blocks with PEN function equal to and
above 10 mm2 (AWG 8) with screw-type or screwless-type clamping units, primarily intended for industrial
applications.
NOTE: AWG is the abbreviation of “American Wire Gage” [Gage (US) = Gauge (…
Low-voltage switchgear and controlgear — Part 7-3: Ancillary equipment — Safety requirements for fus...
1.1 Scope
This part of IEC 60947 applies to fuse terminal blocks with screw-type or screwless-type clamping units
for the connection of rigid (solid or stranded) or flexible copper conductors for the reception of cartridge
fuse-links in accordance with IEC 60127-2, intended primarily for industrial or similar use in circuits not
exceeding 1 000 V a.c., up to 1 000 Hz or 1 500 V d.c., and having a…
1.1 This standard applies to 60 – 250°C single- or multiple-conductor jacketed or unjacketed, integral or
nonintegral cables and single or multiple coaxial cables for telephone and other communication circuits
such as voice, data, and audio for on-premise customer systems. These cables are may contain one or
more optical fibre members. For the purpose of this standard, a coaxial cable or…
1.1 These requirements apply to Factory-Built Type A Chimneys, which do not require field fabrication.
They are for use with gas and liquid fuel-fired residential appliances and building heating equipment,
where the appliance or equipment flue-gas temperatures do not exceed 540 °C. They are intended for use
in accordance with the National Building Code of Canada, CSA-B139.2, Installation Code…
1.1 These requirements apply to factory-built chimney assemblies which do not require field fabrication.
They are for use with gas, liquid and solid fuel-fired residential appliances and building heating equipment,
where the flue-gas temperatures normally do not exceed 650 ºC. They are intended for use in accordance
with the National Building Code of Canada, CSA B139.2, Installation Code for…