1.1 These requirements cover the construction and operation of halocarbon clean agent fire extinguishing
system units intended to be installed, inspected, tested, and maintained in accordance with the Standard
on Clean Agent Fire Extinguishing Systems, NFPA 2001 and with the National Fire Code of Canada.
1.2 These requirements also cover halocarbon clean agent automatic extinguisher units that…
Unités de système d’extinction aux agents propres à l’halocarbure
1.1 Les présentes exigences s’appliquent à la construction et à l’utilisation des unités de système
d’extinction aux agents propres à l’halocarbure conçues pour être installées, inspectées, mises à l’essai
et entretenues en conformité avec la norme NFPA 2001, Standard on Clean Agent Fire Extinguishing
Systems, et avec le Code national de prévention des incendies du Canada.
1.2 Ces exigences s…
These requirements cover the construction and operation of inert gas clean agent fire extinguishing
system units intended to be installed, inspected, tested, and maintained in accordance with the Standard
for Clean Agent Fire Extinguishing Systems, NFPA 2001 and with the National Fire Code of Canada.
Unités de système d’extinction aux agents propres à gaz inerte
Les présentes exigences s’appliquent à la construction et à l’utilisation des unités de système
d’extinction aux agents propres à gaz inerte conçues pour être installées, inspectées, mises à l’essai et
entretenues en conformité avec la norme NFPA 2001, Standard on Clean Agent Fire Extinguishing
Systems, et avec le Code national de prévention des incendies du Canada.
Consensus Standards — Development and Maintenance Process
This document describes the consensus standardization process established by the Bureau de normalisation du Québec (BNQ) to meet the accreditation requirements of the standards development organizations of the Standards Council of Canada (SCC). This process is based on the requirements and guidelines set out in the document Canadian Standards Development — Requirements & Guidance —…
1.1 This standard provides the requirements for modular built relocatable temporary structures.
1.2 Relocatable structures for temporary use are a form of modular construction, built in an approved
offsite facility, designed to be transported to a location, assembled, and utilized. During the life of these
structures they may be used in several different locations.
1.3 The buildings constructed…
1.1
This Standard applies to newly produced, direct gas-fired process air heaters of the recirculating or non- recirculating type (see Clause 3, Definitions), hereinafter referred to as heaters, whose primary purpose is to provide process heating to non-occupied spaces within commercial and industrial buildings and may also include operation as a non-recirculating ventilation air heater (see…
Non-recirculating direct gas-fired heating and forced ventilation appliances for commercial and indu...
1.1
This Standard applies to newly produced, non-recirculating direct gas-fired heating and forced ventilation appliances, hereinafter referred to as heaters, whose purpose is to address building infiltration, replace building air that is exhausted, offset building conduction heat loss and provide outside air ventilation. All air to the heater is ducted directly from outdoors and the products of…
STANDARD FOR EXTERNAL CORROSION PROTECTION SYSTEMS FOR STEEL UNDERGROUND TANKS FOR FLAMMABLE AND COM...
1.1 This Standard covers requirements for external corrosion protection systems on steel non-pressure
tanks that are used for the underground storage of flammable liquids and combustible liquids. The
requirements are structured as follows:
A Section 5, Cathodically Protected Tanks, covers external corrosion protection using sacrificial
magnesium and zinc anodes, low profile nylon isolating…
This National Standard of Canada applies to glazing materials that have been subjected to the test methods
described herein. Such test methods are intended to demonstrate minimum performance characteristics designed
to reduce the likelihood of cutting and piercing injuries resulting when glazing materials used in areas of human
impact (see Annex A) in building and architectural applications…