Household and similar electrical appliances — Safety — Part 2-40: Particular requirements for electr...
This clause of Part 1 is replaced by the following.
This part of IEC 60335 deals with the safety of electric HEAT PUMPS, including SANITARY HOT WATER HEAT PUMPS,
AIR-CONDITIONERS, and DEHUMIDIFIERS incorporating motor-compressors and hydronic room FAN COILS, their
maximum RATED VOLTAGES being not more than 250 V for single phase appliances and 600 V for all other
appliances.
1DV.1 DR…
Household and similar electrical appliances — Safety — Part 2-72: Particular requirements for floor ...
This clause of Part 1 is replaced by the following.
This International Standard deals with the safety of powered ride-on and powered WALK-BEHIND MACHINES
intended for commercial indoor or outdoor use for the following applications:
– sweeping,
– scrubbing,
– wet or dry pick-up,
– polishing,
– application of wax, sealing products and powder based detergents,
– shampooing
of floors with an…
Secondary cells and batteries containing alkaline or other non-acid electrolytes — Safety requiremen...
This International Standard specifies requirements and tests for the safe operation of portable sealed
SECONDARY CELLS and batteries (other than button) containing alkaline or other non-acid electrolyte, under
INTENDED USE and REASONABLY FORESEEABLE MISUSE.
1DV.1 D1 Modification to add the following paragraph and note to Clause 1:
This standard is not, by itself, generally suitable for the…
Accumulateurs alcalins et autres accumulateurs à électrolyte non acide — Exigences de sécurité pour ...
La présente Norme internationale spécifie les exigences et les essais pour le fonctionnement
en sécurité des accumulateurs portables étanches, et accumulateurs (autre que boutons)
contenant un électrolyte alcalin ou un autre électrolyte non acide dans des utilisations
prévues et dans des utilisations abusives raisonnablement prévisibles.
Lève-personnes utilisés pour le déplacement de personnes — Installation, utilisation et entretien
1.1
Cette norme vise les lève-personnes et les accessoires utilisés pour déplacer des personnes et conçus notamment pour suspendre ou soutenir les clients, entre les lits, les chaises, les civières, les bains (ou à d’autres endroits où le client est étendu, assis ou debout). Cette norme vise les lève-personnes fixes
12lève-personnes sur rail au plafond, lève-personnes portables, lève-personnes…
Évaluation des performances énergétiques des climatiseurs et des thermopompes de grande puissance et...
1.1
Cette norme s’applique seulement aux systèmes électromécaniques à compression de vapeur suivants :
a)
les climatiseurs et thermopompes de grande puissance dotés d’une puissance de refroidissement ou de chauffage supérieure à 19 kW (65 000 Btu/h) dans des conditions de performances normalisées, que l’alimentation électrique soit monophasée ou triphasée; et
b)
toutes les tailles de…
1.1 The requirements of this standard cover holders and connectors for electric lamps, including
incandescent, fluorescent, and other electric-discharge-type lamps, rated as indicated in Clause 6, to be
used in accordance with the Canadian Electrical Code (CEC), Part I, C22.1, and the National Electrical
Code (NEC), ANSI/NFPA 70.
1.2 These requirements cover screw lampholders, including those…
1.1
1.1.1
Cette norme énonce les exigences applicables à la planification, à la conception, à la mise en oeuvre, à l’entretien, à l’évaluation et à l’amélioration continue des systèmes signalétiques destinés aux centres de soins de santé.
1.1.2
Cette norme traite des éléments suivants d’un système d’orientation du point de vue de l’expérience de l’usager, du processus, du plan, et du système…
1.1 General
This Standard covers wrought steel buttwelding fittings, including extruded headers and factory-made induction or cold bends, primarily intended for use in oil or gas pipeline systems.
1.2 Size, grade, and category
1.2.1 Size
This Standard covers fittings in sizes from NPS 1/2 to NPS 60. (See Table A.1.)
?
1.2.2 Grade
For other than sour service, this Standard covers fittings…
1.1 General
This Standard covers wrought steel welding neck and blind flanges primarily intended for use in oil or gas pipeline systems.
1.2 Size, grade, nominal pressure class, and category
1.2.1 Size
This Standard covers flanges in sizes from NPS 1/2 to NPS 60. (See Table A.1.)
?
1.2.2 Grade
For other than sour service, this Standard covers flanges from Grade 248 to Grade 690. For sour…