Road vehicles — Dimethyl Ether (DME) fuel system components — Part 1: General requirements and defin...
This document specifies general requirements and definitions of Dimethyl Ether (DME) fuel system components, intended for use on the types of motor vehicles defined in ISO 3833. It also provides general design principles and specifies requirements for instructions and marking.
This document is applicable to vehicles (mono-fuel, bi-fuel or dual-fuel applications) using Dimethyl Ether in accordance…
Road vehicles — Dimethyl Ether (DME) fuel system components — Part 2: Performance and general test m...
This document specifies performance and general test methods for Dimethyl Ether (DME) fuel system components intended for use on the types of motor vehicles defined in ISO 3833.
This document is applicable to vehicles (mono-fuel, bi-fuel or dual-fuel applications) using Dimethyl Ether in accordance with ISO 16861 and ASTM D7901. It is not applicable to the following:
a) fuel containers;
b)…
This document applies only to Dimethyl Ether refuelling connectors hereinafter referred to as devices, constructed entirely of new, unused parts and materials. Dimethyl Ether refuelling connectors consist of the following components, as applicable:
a) Nozzle (mounted on dispenser side).
b) Receptacle (mounted on vehicle).
This document applies to devices which use Dimethyl Ether as fuel,…
Medical devices — Application of risk management to medical devices
This document specifies terminology, principles and a process for risk management of medical devices, including software as a medical device and in vitro diagnostic medical devices. The process described in this document intends to assist manufacturers of medical devices to identify the hazards associated with the medical device, to estimate and evaluate the associated risks, to control these…
Corrosion des métaux et alliages — Détermination de la corrosion occasionnée par les courants altern...
Le présent document spécifie des critères de protection pour la détermination du risque de corrosion due aux courants alternatifs pour les canalisations protégées cathodiquement.
Il s'applique aux canalisations enterrées qui sont protégées cathodiquement et influencées par des systèmes de traction à courant alternatif et/ou des lignes électriques haute tension en courant alternatif.
En…
Corrosion of metals and alloys — Determination of AC corrosion — Protection criteria
This document specifies protection criteria for determining the AC corrosion risk of cathodically protected pipelines.
It is applicable to buried cathodically protected pipelines that are influenced by AC traction systems and/or AC power lines.
In the presence of AC interference, the protection criteria given in ISO 15589-1 are not sufficient to demonstrate that the steel is being protected…
Véhicules routiers — Connecteur de remplissage en Dimethyl Ether (DME)
Le présent document s'applique uniquement aux pistolets et les réceptacles de remplissage en Diméthyl Éther, ci-après dénommés appareils, construits entièrement à partir de pièces neuves et non utilisées, et de matériaux. Les connecteurs de remplissage en Diméthyl Éther sont composés, le cas échéant, des éléments suivants:
a) pistolet (fixé sur le côté borne de remplissage),
b) réceptacle (…
Household and similar electrical appliances - Safety - Part 2-62: Particular requirements for commer...
IEC 60335-2-62:2019 deals with the safety of electrically operated commercial rinsing sinks used in commercial kitchens, their rated voltage being not more than 250 V for single-phase appliances connected between one phase and neutral, and 480 V for other appliances. These appliances are used for example in kitchens of restaurants, canteens, hospitals and commercial enterprises such as bakeries,…
Appareils électrodomestiques et analogues - Sécurité - Partie 2-62: Exigences particulières pour les...
L'IEC 60335-2-62:2019 traite de la sécurité des plonges électriques à usage commercial, utilisées dans les cuisines commerciales et dont la tension assignée n'est pas supérieure à 250 V pour les appareils monophasés alimentés entre phase et neutre, et à 480 V pour les autres appareils. Ces appareils sont par exemple utilisés dans les cuisines de restaurants, les cantines, les hôpitaux…