Non-alloy steel wire rod for conversion to wire — Part 4: Specific requirements for wire rod for spe...
ISO 16120-4:2017 specifies requirements for wire rod for conversion to wire for special applications. It is applicable to non-alloy steel wire rod with improved characteristics intended for drawing and/or cold rolling.
Specifications for particular types of winding wires - Part 70: Polyester glass-fibre wound fused, u...
IEC 60317-70:2017 specifies requirements of polyester glass-fibre wound fused, unvarnished or resin or varnish impregnated, bare or grade 1 or grade 2 enamelled round copper winding wires, temperature index 155. The impregnating agent can be, for instance, epoxy, polyester, or polyesterimide resin based. NOTE - For this type of wire, the heat shock test is inappropriate and therefore a heat shock…
Spécifications pour types particuliers de fils de bobinage - Partie 70: Fil de section circulaire en...
IEC 60317-17:2017 spécifie les exigences relatives au fil de bobinage de section circulaire en cuivre nu ou émaillé de grade 1 ou de grade 2, guipé de fibres de verre polyester fondues non vernies ou imprégnées de vernis ou de résine, d’indice de température 155. L’agent d’imprégnation peut être, par exemple, un matériau à base de résine époxy, de résine de polyester ou de polyesterimide. NOTE -…
Specifications for particular types of winding wires - Part 71: Polyester glass-fibre wound fused an...
IEC 60317-71:2017 specifies requirements of polyester glass-fibre wound fused resin or varnish impregnated bare, grade 1 or grade 2 enamelled round copper winding wire, temperature index 180. The impregnating agent can be, for instance, epoxy, polyester, or polyesterimide resin based. NOTE For this type of wire, the heat shock test is inappropriate and therefore a heat shock temperature cannot be…
Spécifications pour types particuliers de fils de bobinage - Partie 71: Fil de section circulaire en...
IEC 60317-71:2017 spécifie les exigences relatives au fil de bobinage de section circulaire en cuivre nu ou émaillé de grade 1 ou de grade 2, guipé de fibres de verre polyester fondues et imprégnées de vernis ou de résine, d’indice de température 180. L’agent d’imprégnation peut être, par exemple, un matériau à base de résine époxy, de résine de polyester ou de polyesterimide. NOTE - Pour ce type…
Fibre optic communication system design guides - Part 15: Cable plant and link - Testing multi-fibre...
IEC TR 61282-15:2017 provides guidance for the testing of multi-fibre cable, multimode or single-mode, terminated with plugs described in IEC 617547 (all parts) (multiple-fibre push on – MPO). Guidance is provided on the measurement of attenuation, polarity, length and optical return loss. The cabling can be installed in a variety of environments, including residential, commercial, industrial,…
Specifications for particular types of winding wires - Part 0-10: General requirements - Polyester g...
IEC 60317-0-10:2017 specifies the general requirements of polyester glass-fibre wound fused, unvarnished, or resin or varnish impregnated bare, grade 1 or grade 2 or enamelled round copper winding wires. The range of nominal conductor dimensions is given in Table 1, Table 2, Table A.1 and Table A.2.
Keywords: insulated wires used for windings
Spécifications pour types particuliers de fils de bobinage - Partie 0-10: Exigences générales - Fil ...
IEC 60317-0-10:2017 spécifie les exigences générales pour le fil de section circulaire en cuivre nu ou émaillé de grade 1 ou de grade 2, guipé de fibres de verre polyester fondues, non vernies ou imprégnées de résine ou de vernis. La gamme des dimensions nominales des conducteurs est donnée dans le Tableau 1, le Tableau 2, le Tableau A.1 et le Tableau A.2.
Mots clés: fils isolés utilisés pour…