Steel forgings — Testing frequency, sampling conditions and test methods for mechanical tests
ISO 15461:2018 gives guidelines for the simplification and harmonization of the specifications for mechanical testing of open die and closed die forgings in International Standards and other technical delivery conditions for forgings of steel.
ISO 15461:2018
a) offers various options for
the frequency of testing, and
sampling conditions,
b) introduces a designation system for…
Steel flat products for pressure purposes — Technical delivery conditions — Part 3: Weldable fine gr...
ISO 9328-3:2018 specifies the requirements for flat products for pressure equipment made of weldable fine grain steels as specified in Tables A.1 and B.1. The requirements and definitions of ISO 9328‑1 also apply to this document.
NOTE 1 Fine grain steels are understood as steels with a ferritic grain size of 6 or finer when tested in accordance with ISO 643.
NOTE 2 This document offers the…
Steel flat products for pressure purposes — Technical delivery conditions — Part 5: Weldable fine gr...
ISO 9328-5:2018 specifies the requirements for flat products for pressure equipment, made of thermomechanically rolled weldable fine grain steels as specified in Tables A.1 and B.1. The steels are not suitable for hot forming.
Until now, no sufficient data for the standardization of the elevated temperature properties of these steels are available. If their use at such temperatures is intended,…
Steel flat products for pressure purposes — Technical delivery conditions — Part 6: Weldable fine gr...
ISO 9328-6:2018 specifies the requirements for flat products for pressure equipment made of quenched and tempered weldable fine grain steels as specified in Tables A.1 and B.1. The requirements and definitions of ISO 9328‑1 also apply to this document.
NOTE 1 Fine grain steels are understood to be steels with a ferritic grain size of 6 or finer when tested in accordance with ISO 643.
NOTE 2…
1.1 General
1.1.1
This Standard provides guidelines for the commissioning of buildings and all energy and domestic water related building systems. It applies to new construction only for Part 3 buildings, as specified in the National Building Code of Canada (NBC). It does not apply to equipment and systems installed by the owner or others after building completion.
1.1.2
This Standard is intended…
1.1
This Standard, following the principles set out in CAN/CSA-Z1000, specifies requirements for
a)
establishing and maintaining an extreme conditions management system in accordance with occupational health and safety management system (OHSMS) principles;
b)
the roles and responsibilities of the management representative, the monitoring team, and the worker;
c)
management of external service…
Electromagnetic compatibility (EMC) — Part 6-5: Generic standards — Immunity for
equipment used in p...
This part of IEC 61000 specifies EMC immunity requirements which apply to electrical and
electronic equipment intended for use in power stations and substations, as described below.
Immunity requirements for electromagnetic phenomena with spectral contributions in the
frequency range 0 Hz to 400 GHz are covered. No tests need to be performed at frequencies
or for phenomena where no requirements…
Automatic electrical controls — Part 2-7: Particular requirements for timers and time switches
(IEC ...
This clause of Part 1 is applicable except as follows:
1.1 Replacement:
In general, this part of IEC 60730 applies to timers and time switches that may use electricity,
gas, oil, solid fuel, solar thermal energy, etc. or a combination thereof, including heating, air
conditioning and similar applications.
This standard is also applicable to individual timers utilized as part of a control system or…
Safety requirements for electrical equipment for measurement, control and laboratory use — Part 2-20...
1.1 Scope
1.1.1 Equipment included in scope
[Add the following paragraph]
This Standard covers equipment that is intended to be installed or used in accordance with CSA C22.1,
Canadian Electrical Code, Part I.
1.1.2 Equipment excluded from scope
[Replace the third dashed item with the following]
– safety ACTUATORs and SOLENOIDs performing a safety function as covered by CSA C22.2 No. 139;