Standard for Shutoff Valves for Trim and Drain Purposes for Fire Protection Service

Numéro de référence:
ANSI/CAN UL 258
Catégorie de norme:
Norme nationale du Canada - Norme canadienne
Sous-catégorie de norme
Type d’activité d’élaboration de normes:
Nouvelle norme
Code ICS:
13.220.20
Statut:
En cours d'élaboration
Date de début de la période de commentaires OEN:
Date de fin de la période de commentaires des OEN:
Affiché le:

Porté:

Champ d’application

1.1 These requirements cover shutoff valves for trim and drain purposes for fire protection service. This standard covers valve constructions such as ball valves, butterfly valves, globe valves and plug valves.

1.2 These valves are intended for installation and use in accordance with the following standards:

            a)     Low Expansion Foam , NFPA 11;

            b)     Sprinkler Systems, NFPA 13;

            c)     Sprinkler Systems in One- and Two-Family Dwellings and Manufactured Homes, NFPA 13D;

            d)     Sprinkler Systems in Low-Rise Residential Occupancies, NFPA 13R;

            e)     Standpipe and Hose Systems, NFPA 14;

            e)     Water Spray Fixed Systems for Fire Protection, NFPA 15; and

            g)      Stationary Pumps for Fire Protection, NFPA 20.

Raison d’être du projet

Raison d’être du projet
AHJs are increasingly reluctant to use ORDs for regulatory requirements. There is an existing ORD that has surpassed its 5 year maintenance cycle and is no longer valid. Regulators (specifically, the Council of Canadian Fire Marshals and Fire Commissioners) have requested that we convert the ORD into a standard. This activity will result in a joint Canada/US standard. Manufacturers will benefit from reduced administrative burden when product only needs to be tested to a single standard. Regulators will benefit from reduced overlap in standards requirements. Proposal to create Joint Canada-US National Standard by combining requirements from ULC/ORD-C258-03, Shutoff Valves for Trim and Drain Purposes for Fire Protection Service, and the Outline of Investigation UL 258, Shutoff Valves for Trim and Drain Purposes.

Note : L’information ci-dessus a été recueillie et est diffusée par le Conseil canadien des normes (CCN) pour les besoins de son système de notification centralisé et transparent pour l’élaboration de nouvelles normes. Le système permet aux organismes d’élaboration de normes (OEN) accrédités par le CCN et aux membres du public d’être informés des nouveaux travaux d’élaboration de normes au Canada. Il donne aussi aux OEN accrédités la possibilité de repérer et de résoudre les cas de doubles emplois éventuels dans les normes et les travaux de normalisation.

Les OEN sont eux-mêmes responsables du contenu et de l’exactitude de l’information présentée ici. Cette information n’existe que dans la langue dans laquelle elle a été fournie au CCN.