Transformateurs basse tension - Partie 1: Exigences générales

Numéro de référence:
C22.2 No. 66.1-06 (R2011)
Catégorie de norme:
Norme consensuelle d'OEN
Type d’activité d’élaboration de normes:
Confirmation
Statut:
En cours d'élaboration
Date de début de la période de commentaires OEN:
Date de fin de la période de commentaires des OEN:
Affiché le:

Porté:

Champ d’application

.1
These requirements cover the following types of transformers:

a) Air-cooled transformers and reactors for general use;

b) General purpose autotransformers;

c) Ferroresonant transformers;

d) Class 2 and Class 3 transformers (which are evaluated in accordance with Part 3);

e) Cord-connected transformers (which are evaluated in accordance with Part 2);

f) Transformers incorporating overcurrent or over-temperature protective devices, transient voltage surge protectors, or capacitors; and

g) Permanently-connected transformers.

1.2
These transformers are intended to be used in accordance with the National Electrical Code, ANSI/NFPA 70, or CSA C22.1, the Canadian Electrical Code, Part I. The Canadian Electrical Code defines low voltage as any voltage from 31 to 750 V inclusive and high voltage as any voltage above 750 V. The National Electrical Code, ANSI/NFPA 70, defines low voltage as any voltage up to 600 V, nominal. Therefore, low voltage transformers intended for use in Canada may be rated above 600 V up to 750 V. Low voltage transformers intended for use in the United States are rated up to 600 V. Where information in clauses and tables in this standard reference voltage ranges, the limit of 600 V applies in the United States, while the limit of 750 V applies in Canada.

1.3
The standard does not cover the following transformers:

a) Direct plug-in types;

b) Neon;

c) Liquid-immersed;

d) Variable voltage (Variac);

e) Low voltage landscape;

f) Swimming pool and spa:

g) Ignition;

h) High intensity lighting;

i) Toy;

j) Fluorescent lamp types;

k) Transformers for welders;

l) Distribution;

m) Transformers intended for use in the United States with a nominal primary rating of more than 600 V;

n) Transformers incorporating rectifying or waveshaping circuitry;

o) Transformers for use with radio- and television-type appliances;

p) Transformers intended for use in the United States having overvoltage taps rated over 660 V;

q) Autotransformers used in industrial control equipment, which are evaluated in accordance with the requirements of the Standard for Industrial Control Equipment, UL 508, or CSA C22.2 No. 14, Industrial Control Equipment; and

r) Other special types of transformers covered in requirements for other electrical devices or appliances.

1.4
Part 1, as well as Part 2 and Part 3, establish the characteristics, construction, operating conditions, markings, and test conditions for each type of transformer.

1.5
The requirements in this standard may be modified by requirements in an end product standard if a transformer is intended for use only as a component in other equipment.
 

Note : L’information ci-dessus a été recueillie et est diffusée par le Conseil canadien des normes (CCN) pour les besoins de son système de notification centralisé et transparent pour l’élaboration de nouvelles normes. Le système permet aux organismes d’élaboration de normes (OEN) accrédités par le CCN et aux membres du public d’être informés des nouveaux travaux d’élaboration de normes au Canada. Il donne aussi aux OEN accrédités la possibilité de repérer et de résoudre les cas de doubles emplois éventuels dans les normes et les travaux de normalisation.