Stockage des hydrocarbures dans les formations souterraines
Porté:
1.1
This Standard sets out minimum requirements for the design, construction, operation, maintenance, abandonment, and safety of hydrocarbon storage in underground reservoir formations and associated equipment. The equipment considered includes
(a) storage wellhead and Christmas tree assemblies;
(b) wells and subsurface equipment; and
(c) safety equipment, including monitoring, control, and emergency shutdown systems.
Note: Hydrocarbons covered by this Standard are restricted to natural gas.
1.2
The scope of this Standard is shown in Figure 1.
1.3
This Standard does not apply to
(a) underground storage facilities for gases or fluids other than hydrocarbons, such as storage facilities used for air storage, unless these fluids are used specifically for the displacement of stored hydrocarbons;
(b) underground storage facilities used for storing substances other than hydrocarbons, such as reaction chambers and waste disposal facilities;
(c) underground storage in overburden materials involving the use of tanks, such as gasoline tanks;
(d) design and fabrication of pressure vessels that are covered by pressure vessel codes;
(e) heat exchangers, pumps, compressors, and piping in processing plant facilities, manufacturing plants, or industrial plants that are covered by appropriate codes;
(f) gathering lines, flow lines, metering, compressors, and associated surface equipment beyond the first emergency shutdown valve (ESV) or block valve; and
(g) storage of hydrocarbons containing hydrogen sulphide in concentrations greater than 10 mol/kmol.
1.4
It is not the intent of this Standard to prevent the development of new equipment or practices, nor to prescribe how such innovations should be handled.
1.5
Where the requirements of this Standard differ from the requirements of other standards or codes referenced herein, the requirements of this Standard take precedence.
1.6
The requirements of this Standard do not apply retroactively to existing installations and installations under construction at the time of publication, but they do apply to the extension, replacement, maintenance, and upgrading of such installations.
1.7
In CSA Standards, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; "should" is used to express a recommendation or that which is advised but not required; "may" is used to express an option or that which is permissible within the limits of the standard; and "can" is used to express possibility or capability.
Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material.
Notes to tables and figures are considered part of the table or figure and may be written as requirements.
Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application
Raison d’être du projet
Note : L’information ci-dessus a été recueillie et est diffusée par le Conseil canadien des normes (CCN) pour les besoins de son système de notification centralisé et transparent pour l’élaboration de nouvelles normes. Le système permet aux organismes d’élaboration de normes (OEN) accrédités par le CCN et aux membres du public d’être informés des nouveaux travaux d’élaboration de normes au Canada. Il donne aussi aux OEN accrédités la possibilité de repérer et de résoudre les cas de doubles emplois éventuels dans les normes et les travaux de normalisation.
Les OEN sont eux-mêmes responsables du contenu et de l’exactitude de l’information présentée ici. Cette information n’existe que dans la langue dans laquelle elle a été fournie au CCN.