À haute intensité de chauffage à infrarouge au gaz

Logo
CSA Group
Organisme d'élaboration de normes:
Programme de travail:
Numéro de référence:
CSA 2.35
Catégorie de norme:
Norme consensuelle d'OEN
Type d’activité d’élaboration de normes:
Nouvelle version
Statut:
En cours d'élaboration
Date de début de la période de commentaires OEN:
Date de fin de la période de commentaires des OEN:
Affiché le:

Porté:

Champ d’application

1.1.1
This standard applies to newly produced, gas-fired high-intensity infrared heaters (see Part IV, Definitions), hereinafter referred to as heaters or appliances, constructed entirely of new, unused parts and materials with inputs up to and including 400,000 Btu per hour (117 228 W) per burner:
a. For use with natural gas;
b. For use with manufactured gas;
c. For use with mixed gas;
d. For use with liquefied petroleum (propane) gases;
e. For use with LP gas-air mixtures; or
f. Convertible for use with natural gas and liquefied petroleum (propane) gases, when provision is made for the simple conversion from one gas to the other.

1.1.2
The heaters covered by this standard are intended for installation in and heating of outdoor spaces or nonresidential indoor spaces and are intended for location where flammable gases or vapors are not generally present.

Although heaters covered by this standard may, in certain instances, be suitable for application in industrial processes, this standard does not cover industrial process burners.

1.1.3 
High-intensity infrared heaters may be suspended overhead, angle mounted overhead, wall mounted or floor mounted. Floor-mounted heaters may be free-standing and, when for outdoor installation, also may be portable to the extent defined in Part IV,Definitions.

1.1.4 
Overhead heaters complying with this standard are suitable for use in (1) aircraft hangars when installed in accordance with the Standard for Aircraft Hangars, ANSI/NFPA 409, and (2) garages when installed in accordance with the Standard for Parking Structures, ANSI/NFPA 88A, or the Standard for Repair Garages, ANSI/NFPA 88B; or the Canadian Natural Gas and Propane Installation Code, CSA B149.1, and are so marked.

1.1.5
The heaters covered by this standard may be:
a. Designed for connection to a vent; or
b. Not designed for connection to a vent.

Note : L’information ci-dessus a été recueillie et est diffusée par le Conseil canadien des normes (CCN) pour les besoins de son système de notification centralisé et transparent pour l’élaboration de nouvelles normes. Le système permet aux organismes d’élaboration de normes (OEN) accrédités par le CCN et aux membres du public d’être informés des nouveaux travaux d’élaboration de normes au Canada. Il donne aussi aux OEN accrédités la possibilité de repérer et de résoudre les cas de doubles emplois éventuels dans les normes et les travaux de normalisation.