Affiner les résultats
Affichage de 3577 - 3588 de 11615
Avis d'intention
Clapets antiretour et clapets de retenue en fonte...
La présente norme spécifie les principales caractéristiques des clapets antiretour en thermoplastique ayant un diamètre nominal jusqu’à 200 mm (8 po) ou en fonte ayant un diamètre nominal jusqu’à 375 mm (15 po) et les...
Avis d'intention
Appareils de jardinage motorisés
.1 This Standard applies to motor-operated gardening appliances* intended for use on nominal system voltages of 250 V and less and in nonhazardous locations, and designed to be used in accordance with the Rules of the...
Avis d'intention
Code pour le gaz de digesteur, gaz d'enfouissement...
1.1 General 1.1.1 This Code applies to the installation of systems for the production, handling, storage, and utilization of digester gas in newly constructed wastewater treatment plants, as well as additions to, and the...
Avis d'intention
Installation des thermopompes à air et des climatiseurs
1.1 This Standard covers the installation requirements for unitary air conditioners and air source heat pumps for residential applications with cooling ratings up to 19 kW (65 000 Btu/h). 1.2 This Standard covers...
Avis d'intention
Appareils élévateurs d'habitation pour personnes...
.1 Application of Requirements This Standard specifies minimum requirements for the design, construction, installation, and operation of elevating devices that are to be used by persons with physical disabilities travelling...
Avis d'intention
Radiateurs portatifs de mazout industriels
1. Scope 1.1 This Standard applies to portable industrial oil-fired heaters irrespective of the heating capacity, the type of burner or the motive power. 1.2 The requirements given herein apply to units which may be indirect...
Avis d'intention
Liquid Portable Alimentés Appliances catalytiques
1.1 This Standard applies to non-pressurized liquid fuelled catalytic appliances ranging in input capacities from 1,000 Btuh to 15,000 Btuh primarily used as portable space heating appliances. 1.2 Appliances with input...
Avis d'intention
Appareils de chauffage à air chaud au mazout ...
1.1 This Standard applies to oil-fired forced warm-air heating appliances for installation in mobile housing and recreational vehicles, irrespective of the heating capacity or the type of burner used. 1.2 This Standard...
Avis d'intention
Performances des enseignes de sortie à éclairage...
1.1 This Standard provides performance requirements and test methods for evaluating power consumption of internally lighted exit signs. Note: Visibility requirements are contained in CSA C22.2 No. 141. 1.2 Exit signs...
Avis d'intention
Vault Ventilators and Vault Ventilating Ports
1.1 These requirements cover emergency vault ventilators and vault-ventilating ports. 1.2 Emergency vault ventilators are primarily intended to provide fresh air to persons locked in the vault by accident or during a robbery...
Avis d'intention
Standard Test Method for the Determination of...
1.1 This test method determines combustibility parameters for the assessment of degree of combustibility of building materials by measuring the heat release and smoke production from specimens exposed to radiant heat using...
Avis d'intention
Norme relative aux hottes d’aspiration et aux...
1.1 Les exigences de cette norme s’appliquent aux hottes d’aspiration des cuisines professionnelles et collectives conçues pour être placées au-dessus du matériel de cuisson pour restaurant comme les cuisinières, grilloirs...