1 Scope
1.1
This Standard applies to the following products to be installed in accordance with the Canadian Electrical Code, Part I:
a)
cords and insulated conductors intended for decorative lighting and seasonal-use cord sets; and
b)
insulated conductors intended for internal wiring of electrical equipment, for leads of transformers, motors, etc., and for luminous-tube signs and ignition…
1 Scope
1.1 This Part is intended to be read together with the Standard for Fuseholders – Part 1: General
Requirements, hereafter referred to as Part 1. The titles of the Clauses in this Part correspond to the
similarly titled Clauses in Part 1. The requirements of Part 1 apply unless modified by this Part. For the
Part 1 requirements, refer to the Standard for Fuseholders – Part 1: General…
1 Scope
1.1 This Part is intended to be read together with the Standard for Fuseholders – Part 1: General
Requirements, hereafter referred to as Part 1. The titles of the Clauses in this Part correspond to the
similarly titled Clauses in Part 1. The requirements of Part 1 apply unless modified by this Part. For the
Part 1 requirements, refer to the Standard for Fuseholders – Part 1: General…
Medical electrical equipment — Part 2-43: Particular requirements for the basic safety and essential...
Scope
Replacement:
This document applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of both FIXED and
MOBILE X-RAY EQUIPMENT declared by the MANUFACTURER to be suitable for RADIOSCOPICALLY
GUIDED INTERVENTIONAL PROCEDURES, hereafter referred to as INTERVENTIONAL X-RAY EQUIPMENT.
Its scope excludes, in particular:
– equipment for RADIOTHERAPY;
– equipment for COMPUTED TOMOGRAPHY;
–…
Household and similar electrical appliances — Safety — Part 2-41: Particular requirements for pumps ...
1 Scope
This clause of Part 1 is replaced by the following.
This International Standard deals with the safety of electric pumps for liquids having a
temperature not exceeding 90 °C, intended for household and similar purposes, their rated
voltage being not more than 250 V for single-phase appliances and 480 V for other
appliances.
NOTE 101
This Standard covers both permanently…
Lamp controlgear — Part 1: General and safety requirements Appareillages de lampes — Partie 1 : ...
1 Scope
This Standard specifies general and safety requirements for lamp controlgear designed to be installed
on branch circuits not exceeding 600 V nominal between conductors and used in accordance with
CSA C22.1, Canadian Electrical Code, Part I.
This standard also covers lamp controlgear for lamps which are not yet standardized.
Tests dealt with in this standard are type tests.…