Gas-fired low pressure steam and hot water boilers
This Standard applies to newly produced gas-fired low-pressure steam and hot water boilers with gas inlet pressure ratings not exceeding 0.5 psi (3.5 kPa) and having input ratings of less than 12,500,000 Btu/hr (3 663 389 W) (see Clause 3, Definitions), hereinafter referred to as boilers*, constructed entirely of new unused parts and materials, for operation at or below the following pressures…
1.1
1.1.1
This Standard establishes requirements for the planning, design, implementation, maintenance, evaluation, and continual improvement of wayfinding systems for HCFs.
1.1.2
This Standard addresses the following components of wayfinding as a user experience, a process, a plan, and a system:
a)
place;
b)
people;
c)
elements; and
d)
continual improvement.
1.2
This Standard sets…
Safe installation and operation of hemodialysis and peritoneal dialysis in a home setting
1 Scope
1.1
This Standard specifies requirements for the safe installation and operation of hemodialysis and peritoneal dialysis performed in a home setting. It is intended for use by dialysis providers, including health care workers and professionals who perform technical and operational functions associated with home dialysis, as well as stakeholders who have an interest in safety or related…
1.1
This Standard is intended to form the basis of a QMS within a health care or home setting for the purpose of providing safe, reliable kidney dialysis treatments.
Note: A comprehensive QMS can be achieved when this Standard is used in combination with the following related Standards:
a)
CAN/CSA-C22.2 No. 60601-1;
b)
CAN/CSA-C22.2 No. 60601-2-16;
c)
CAN/CSA-C22.2 No. 60601-2-39;
d)…
Lifts for the transfer of persons — Installation, use, and maintenance
1.1
This Standard applies to lifts and accessories used to transfer persons, specifically by suspending from above or supporting from below, between beds, chairs, stretchers, bathtubs, or other similar resting places or standing. This Standard applies to fixed and mobile lifts, lifting arm- or rail-mounted, including lifts often referred to as ceiling-lifts, portable-lifts, floor-lifts, sit-to-…
Mobile elevating work platforms — Design, calculations, safety requirements and test methods
verification, for all types and sizes of mobile elevating work platforms (MEWPs) intended for moving persons to
working positions. It gives the structural design calculations and stability criteria, construction, safety
examinations and security tests to be applied before a MEWP is first put into service, identifies the hazards
arising from the use of MEWPs and describes methods for the…
Mobile elevating work platforms — Safety principles, inspection, maintenance and operation
This International Standard applies to all mobile elevating work platforms (MEWPs) that are
intended to position persons, tools and materials and which, as a minimum, consists of a work
platform with controls, an extending structure and a chassis.
The technical safety requirements of this International Standard apply except where national or
local regulations are more stringent.
For related…
Mobile elevating work platforms — Operator (driver) training
This International Standard provides methods for preparing training materials and administering
standardized training to operators (drivers) of mobile elevating work platforms (MEWPs).
It is applicable to MEWPs, as defined in ISO 16368, intended to move persons, tools and materials to
positions where they can carry out work from the work platform.
NOTE National or other regulations, which…
1.1
This Standard applies to cord-connected and permanently connected electrically heated commercial cooking appliances for use on nominal system voltages of 600 V and less, that are intended to be used in accordance with CSA C22.1, Canadian Electrical Code, Part I.
1.2
This Standard applies to electric ranges, ovens, broilers, fry kettles, griddles, sandwich toasters, toasters, food warmers,…
1.1
This Standard covers the electrical, fire, and shock hazard requirements for all permanently and cord- connected signal equipment intended for household, commercial and industrial use operating at
a)
nominal system voltage of 120 V for household use;
b)
nominal system voltages up to 600 V for commercial and industrial use; and
c)
double insulated equipment up to 240 V.
in non-…