Interrupteurs pour appareils – Partie 2-1: Exigences particulières pour les interrupteurs pour câbles souples

Logo
CSA Group
Organisme d'élaboration de normes:
Programme de travail:
Numéro de référence:
C22.2 NO. 61058-2-1
Catégorie de norme:
Norme nationale du Canada - Adoption d'une Norme internationale
Sous-catégorie de norme
Type d’activité d’élaboration de normes:
Nouvelle norme
Code ICS:
29.120.40
Statut:
En cours d'élaboration
Date de début de la période de commentaires OEN:
Date de fin de la période de commentaires des OEN:
Affiché le:

Porté:

Champ d’application

Clause 1 of IEC 61058-1:2016 is applicable except as follows: 

Addition: 
This document applies to cord switches (mechanical or electronic) for appliances actuated by hand, by foot or by other human activity, to operate or control electrical appliances and other equipment for household or similar purposes with a rated voltage not exceeding 250 V and a rated current not exceeding 16 A. 

Throughout this document, the word "appliance" means "appliance or equipment". 

These switches are intended to be operated by a person, via an actuating member or by actuating a sensing unit. The actuating member or sensing unit can be integral or arranged separately from the switch. The transmission of a signal between the actuating member or sensing unit and the switch can be made either physically or electrically (for example, electrical, optical, acoustic or thermal). 


Switches which incorporate additional control functions governed by the switch function are within the scope of this document. 

This document also covers the indirect actuation of the switch when the operation of the actuating member or sensing unit is provided by a remote control or a part of an appliance such as a door. 

NOTE 1 Electronic switches can be combined with mechanical switches giving full disconnection or 
micro-disconnection. 

NOTE 2 Electronic switches without a mechanical switch in the supply circuit provide only electronic 
disconnection. Therefore, the circuit on the load side is always considered to be live. 

NOTE 3 For switches used in tropical climates, additional requirements can apply. 

NOTE 4 Attention is drawn to the fact that the standards for appliances can contain additional or alternative 
requirements for switches. 

Raison d’être du projet

Raison d’être du projet
To align Canadian requirements with those of international standards in the cord switches subject area (adoption of new standard). This proposed New Standard is being developed at the request of the North American Industry and harmonized committee. It will provide the industry with international requirements on cord switches. This will meet the strategic needs of the following key interests: a) ensuring that the latest innovative/technology/safety features are available for users, b) addressing needs of regulators by providing suitable requirements; and c) supporting certification bodies.

Note : L’information ci-dessus a été recueillie et est diffusée par le Conseil canadien des normes (CCN) pour les besoins de son système de notification centralisé et transparent pour l’élaboration de nouvelles normes. Le système permet aux organismes d’élaboration de normes (OEN) accrédités par le CCN et aux membres du public d’être informés des nouveaux travaux d’élaboration de normes au Canada. Il donne aussi aux OEN accrédités la possibilité de repérer et de résoudre les cas de doubles emplois éventuels dans les normes et les travaux de normalisation.